Model VD 115 | Vacuum drying chambers for non-flammable solvents

Benefits
  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe work thanks to proven safety concept
  • Also option of modular complete system with vacuum pump and pump chamber

Configure your product with options and accessories and request it directly here.

Product description

BINDER’s VD series vacuum drying chambers deliver impressive performance through their precise temperature control and gentle drying. The patented expansion rack technology from BINDER also optimizes heat transfer. The shelves can be repositioned for flexible placement and the interior of the chamber is easy to clean.

Important characteristics

  • Temperature range: +9°C above ambient temperature to +220 °C
  • Controller with digital display of pressure and temperature
  • Program-controlled drying monitoring with automatic ventilation at end of process
  • Internal data logger, measured values can be read out in open format via USB
  • 1 aluminum expansion rack, can be custom-positioned
  • Inert gas connection
  • Universal access port DN 16 - for the introduction of external measuring devices
  • Shatterproof, spring-mounted safety glass panel
  • Large viewing window with option of interior lighting
  • Computer interface: Ethernet

Technical specifications

Data
DesignationVD115-230VVD115UL-120V
Article Number9630-00039630-0007
Option model

Standard

Standard

Performance Data Temperature
Temperature range+9 °C above ambient temperature to 220 °C+9 °C above ambient temperature to 220 °C
Temperature uniformity at 100°C2.9 ± K2.9 ± K
Temperature fluctuation at 100°C0.1 ± K0.1 ± K
Heating up time to 100°C130 min130 min
Vacuum Data
Leak rate0,01 bar/h0,01 bar/h
Pressure fluctuation over time at 50 mbar1 ± mbar1 ± mbar
Pressure fluctuation over time at 400 mbar70 ± mbar70 ± mbar
Electrical data
Rated Voltage200...230 V100...120 V
Power frequency50/60 Hz50/60 Hz
Nominal power1,6 kW1,6 kW
Unit fuse10,0 A20,0 A
Phase (Nominal voltage)1~1~
Connections
Vacuum connection with small flange16 DN mm16 DN mm
Measuring access port with small flange16 DN mm16 DN mm
Compressed air connection for pressure-encapsulation5 NW5 NW
Dimensions and weights
Interior volume4 cu.ft.4 cu.ft.
Net weight of the unit (empty)322 lbs322 lbs
Load per rack44 lbs44 lbs
Permitted load154 lbs154 lbs
Wall clearance back3,94 in3,94 in
Wall clearance sidewise2,76 in2,76 in
Housing dimensions not incl. fittings and connections
Width net29.25 in29.25 in
Height net37.09 in37.09 in
Depth net22.87 in22.87 in
Internal Dimensions
Interior width19.92 in19.92 in
Interior height19.92 in19.92 in
Interior depth18.11 in18.11 in
Unit doors11
Environment-specific data
Sound-pressure level40 dB(A)40 dB(A)
Energy consumption at 100°C230 Wh/h230 Wh/h
Fixtures
Number of shelves (std./max.)1/61/6

Downloads

VD | VDL series

pdf, 1.18 MB

Vacuum pump VP1

pdf, 660.24 KB

Vacuum pump VP2

pdf, 637.43 KB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

Vacuum drying chambers (VD | VDL series) - How Aesculap uses BINDER chambers for quality testing

B | Braun Aesculap AG

pdf, 180.57 KB

Vacuum drying chambers (VD series) - Vacuum drying chambers used to dry jewelry gently

Schofer Pforzheim

pdf, 214.9 KB

VD series

pdf, 10.81 MB

VP Pump Modules for Vacuum Drying Ovens VD and VDL

pdf, 4.75 MB

Data Sheet Model VD 115

pdf, 304.9 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Connection kit VD VP1-VP2

For vacuum pump VP1 and VP2. Consisting of plastic hose 1.9 m long, clamping ring, universal centering ring and small flange adapter DN 16 to hose nozzle DN 10

8012-2613

Vacuum pump VP1

Chemical membrane pump with a nominal air flow of 2.0 m³/h and final pressure 7 mbar. Option model can be switched between 230V/50Hz and 120V/60Hz. 

5013-0256

Vacuum pump VP1 front

Vacuum pump VP1 - Chemical membrane pump with a nominal air flow of 2.0 m³/h and final pressure 7 mbar. Option model can be switched between 230V/50Hz and 120V/60Hz. 

Vacuum pump VP2

Chemical membrane pump with a nominal air flow of 3.4 m³/h and final pressure 1.5 mbar. Option model can be switched between 230V/50Hz and 120V/60Hz

5013-0257

Vacuum pump VP2 front

Vacuum pump VP2 - Chemical membrane pump with a nominal air flow of 3.4 m³/h and final pressure 1.5 mbar. Option model can be switched between 230V/50Hz and 120V/60Hz.

Options/Accessories

For vacuum pump VP1 and VP2. Mounting kit for upgrading the pump with a condenser for recovering emissions

8012-2615

Expansion racks

Aluminum

8012-2057

Expansion racks

Expansion racks - aluminum

Expansion racks

Stainless steel

8012-2257

Expansion racks

Expansion racks - stainless steel

Pump chamber VD 115 with vacuum pump VP1

Pump chamber for installation of vacuum pumps, with switchable power socket. Including chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar and connection kit VD VP1-VP2.. 230 V / 50-60 Hz option model

8012-2624

Optional equipment: Pump module with vacuum pump

Pump chamber VD 115 with vacuum pump VP1 - 230 V / 50-60 Hz option model, Pump chamber for installation of vacuum pumps, with switchable power socket. Including chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar and connection kit VD VP1-VP2.

Pump chamber VD 115 with vacuum pump VP 2

Pump chamber for installation of vacuum pumps, with switchable power socket. . 230 V / 50-60 Hz option model

8012-2625

Optional equipment: Pump module with vacuum pump

Pump chamber VD 115 with vacuum pump VP 2 - 230 V / 50-60 Hz option model, Pump chamber for installation of vacuum pumps, with switchable power socket. 

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-0916

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-0919

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1127

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1145

Temperature measurement of the specimen

With flexible Pt 100 sensor and digital specimen temperature display

8612-0006

8612-0006-Objekttemperaturmessung-100x85_Web_670x515.jpg

Temperature measurement of the specimen - with flexible Pt 100 sensor and digital specimen temperature display

Door lock

Lockable door handle

8612-0002

Door lock

Door lock - lockable door handle

Universal access port

Additional DN 40 small flange universal access port with blind flange, for positioning sensors or supply lines in the chamber

8612-0003

Additional universal ventilation

Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread. 

8612-0001

8612-0001-Zusätzliche-Universalbelüftung-100-85_Web_670x515.jpg

Additional universal ventilation - Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread. 

Interior lighting

LED light strips on the left and right in the door

8612-0005

8612-0005-Innenbeleuchtung-100-85_Web_670x515.jpg

Interior lighting - LED light strips on the left and right in the door

Analog output 4-20 mA

For temperature and pressure values (output not adjustable)

8612-0004

8612-0004-Analogausgang-4-20-mA-100x85_Web_670x515.jpg

Analog output 4-20 mA - for temperature and pressure values (output not adjustable)

Touchscreen controller

Large display panel with intuitive operation, actual and set values of main process parameters are shown simultaneously on the display. In addition, the graphic chronological evaluation of  process parameters is displayed

8612-0015

Touchscreen Controller

Touchscreen controller - Large display panel with intuitive operation, actual and set values of main process parameters are shown simultaneously on the display. In addition, the graphic chronological evaluation of  process parameters is displayed.

Calibration certificate, pressure

Calibration of the pressure display to a specified value, including certificate 

8012-2021

Calibration certificate, pressure

Calibration of the pressure display to a specified value, including certificate 

8012-2022

Expansion racks

Stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration

8612-0013

Expansion racks

Expansion racks - stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration

Door gasket

Made of FKM, silicone-free

8612-0009

8612-0009-Türdichtung-aus-FKM-silikonfrei-für-VD-VDL115-100x85_Web_670x515.jpg

Door gasket - made of FKM, silicone-free  

Sorry, no result could be found. Check the spelling or use a new search term.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0710

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0510

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0020

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0120

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

VAP 1 vacuum pump maintenance

Maintenance service of the VAP 1 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0158 included in the scope of services) as well as final functional test. Travel to be quoted as separate

DL20-0410

Services

VAP 1 vacuum pump maintenance - Maintenance service of the VAP 1 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0158 included in the scope of services) as well as final functional test. Travel to be quoted as separate.

VAP 2 vacuum pump maintenance

Maintenance service of the VAP 2 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0159 included in the scope of services) as well as final functional test. Travel to be quoted as separate

DL20-0420

Services

VAP 2 vacuum pump maintenance - Maintenance service of the VAP 2 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0159 included in the scope of services) as well as final functional test. Travel to be quoted as separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0615

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0880

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0980

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0160

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Temperature measurement, 15 measuring points

Temperature measurement with 15 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate

DL30-0218

Services

Temperature measurement, 15 measuring points - Temperature measurement with 15 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.

Pressure calibration

Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate

DL30-0410

Services

Pressure calibration - Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate.

Pressure calibration

Expansion – Additional Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate

DL30-0411

Services

Pressure calibration - Expansion – Additional Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate.

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL42-0310

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Compare products:

Or add another product.