Model 28
Model 28
Dimensions
Product image
Product image
Product image

Model E 28 | Drying and heating chambers with mechanical adjustment

Benefits
  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

Configure your product with options and accessories and request it directly here.

Product description

With a BINDER E series heating oven, you obtain a reliable and powerful unit in a solid configuration at a very attractive price. This heating oven is preferred for tasks in basic research, as well as in human and veterinary medicine.

Important characteristics

  • Temperature range: 60 °C to 230 °C
  • Adjustable exhaust air flap
  • Hydro-mechanical thermostat
  • Class 1 temperature limitation device
  • Timer 0 – 120 min
  • 2 chrome-plated racks

Technical specifications

Designation
Article Number
Option model
Temperature range
Temperature range without illumination cassettes
Temperature range with 100% illumination
Temperature uniformity dependent on set value
Temperature uniformity at -80°C
Temperature uniformity with 100% illumination
Temperature uniformity without illumination cassettes
Temperature uniformity at 37°C
Temperature uniformity at 100°C
Temperature uniformity at 150°C
Temperature fluctuation dependent on set value
Temperature fluctuation at -80°C
Temperature fluctuation at 37°C
Temperature fluctuation with 100% illumination
Temperature fluctuation without illumination cassettes
Temperature fluctuation at 100°C
Temperature fluctuation at 150°C
Heating up time to 100°C
Heating up time to 150°C
Heating up time to 37°C
Average heating-up rate according to IEC 60068-3-5
Cooling down time from 110°C to -40°C
Cooling down time from 180°C to -40°C
Cooling down time from 180°C to -70°C
Cooling down time from 22°C to -80°C
Average cooling down time according to IEC 60068-3-5
Max. heat compensation at 37°C
Max. heat compensation at 40°C
Max. heat compensation at 40°C with illumination
Recovery time after door was opened for 30 s at 150°C
Recovery time after door was opened for 30 s at 37°C
Temperature range with humidity and without illumination cassettes
Temperature range with humidity and 100% illumination
Temperature range with humidity
Humidity range
Humidity range without illumination cassettes
Humidity range with 100% illumination
Temperature uniformity at 25°C and 60% RH
Temperature uniformity at 40°C and 75% RH
Temperature uniformity with illumination at 25°C and 60% RH
Temperature uniformity with illumination at 40°C and 75% RH
Temperature uniformity with humidity dependent on set value
Temperature fluctuation at 25°C and 60% RH
Temperature fluctuation at 40°C and 75% RH
Temperature fluctuation with illumination at 25°C and 60% RH
Temperature fluctuation with illumination at 40°C and 75% RH
Temperature fluctuation with humidity dependent on set value
Humidity fluctuation at 25°C and 60% RH
Humidity fluctuation at 40°C and 75% RH
Humidity fluctuation with illumination at 25°C and 60% RH
Humidity fluctuation with illumination at 40°C and 75% RH
Humidity fluctuation with humidity dependent on set value
Recovery time after door was opened for 30 s at 25°C and 60% RH
Recovery time after door was opened for 30 s at 40°C and 75% RH
Recovery time after door was opened for 30 s with illumination at 25°C and 60% RH
Recovery time after door was opened for 30 s with illumination at 40°C and 75% RH
Max. heat compensation at 25°C and 90% RH
CO₂ range
CO₂ measuring technology
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂
Standard O₂ control range
O₂ control ranges with option: O₂ range
O₂ recovery time after door was opened for 30 s at 5 vol. % O₂
ICH compliant illumination for photo stability testing
ICH compliant illumination for photo stability testing
Daylight tubes
Daylight tubes
Fluora® growth lamps
Arabidopsis lamps
Air circulation (approx.)
Volumetric flow rate of exhaust air acc. to EN 1539 at 50 °C
Air change rate at 100°C
Air change rate at 150°C
Permitted end vacuum
Leckrate
Pressure fluctuation over time at 50 mbar
Pressure fluctuation over time at 400 mbar
Highest permitted solvent quantity (at T-180°C, M-100g/mol, U-40g/m3, K=0,5)
Rated Voltage
Power frequency
Nominal power
Unit fuse
Phase (Nominal voltage)
Vacuum connection with small flange
Measuring access port with small flange
Inert gas connection with flow limiter (RP")
Compressed air connection for pressure-encapsulation
Interior volume
Net weight of the unit (empty)
Load per rack
Permitted load
Wall clearance back
Wall clearance sidewise
Width net
Height net
Depth net
Interior width
Interior height
Interior depth
Viewing window width
Viewing window height
Inner doors
Unit doors
Sound-pressure level
Average heat compensation at set value -80°C and Ta = 21°C
Energy consumption at 25°C and 60% RH
Energy consumption at 100°C
Energy consumption at 150°C
Energy consumption at 20°C
Energy consumption at 37°C
Energy consumption at 37°C and 75% RH
Energy consumption at 37°C and with illumination
Energy consumption at 40°C and 75% RH
Energy consumption at 85°C and 85% RH
Energieverbrauch bei Sollwert -80 °C und Tᵤ = 20 °C
Number of shelves (std./max.)
Number of illumination cassettes (std./max.)
Freezer racks per compartment
Cryoboxes, 50 mm

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

B | E series

pdf, 6.05 MB

Data Sheet Model E 28

pdf, 363.41 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack

Chrome plated

8012-2032

Shelves

Rack - chrome plated

Shelf, perforated

Stainless steel

8012-2160

Shelf

Shelf, perforated - Stainless steel

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Rubber pads

Set anti-slip feet

8012-0702

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1114

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1133

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0815

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0915

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0601

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0110

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0160

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0530

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

Compare products: