slide 2 of 5
Model CB-S 260 | CO2 incubators with hot air sterilization
Benefits
- Safe – cell cultures receive maximum protection against contamination
- Reliable – constant well-being conditions for the cells
- Smart – simple routine cleaning and convenient operation
- Economical – efficient operation without consumables
Product description
The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180°C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO₂ measurements conducted in real time.
Important characteristics
Temperature range:
+6°C above ambient temperature to +50°C
Humidity range:
90 to 95% RH
CO₂ control range:
0 to 20 vol.% CO₂
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Humidification system with condensation protection
- CO2 gas mixing jet with Venturi effect
- CO2 sensor with infrared technology
- LCD to display temperature and CO2 along with additional information and alarms
- Internal data logger, measured values can be read out in open format via USB
- Tightly fitted inner door made of safety glass
- Seamless stainless steel inner chamber
- Perforated shelves, stainless steel
- Troubleshooting system with visual and acoustic alarms
Interfaces:
Ethernet, USB, zero-voltage alarm contact
- Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size
Technical specifications
Designation | CBS260-230V | CBS260UL-120V |
Article Number | 9640-0003 | 9640-0004 |
Option model | Standard | Standard |
Designation | CBS260-230V | CBS260UL-120V |
Temperature range | +6 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C |
Temperature uniformity at 37°C | 0.4 ± K | 0.4 ± K |
Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K |
Recovery time after door was opened for 30 s at 37°C | 8 min | 8 min |
Designation | CBS260-230V | CBS260UL-120V |
Humidity range | 90 ...95 % r.F. | 90 ...95 % r.F. |
Designation | CBS260-230V | CBS260UL-120V |
CO₂ range | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ |
CO₂ measuring technology | IR | IR |
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ | 5 min | 5 min |
Designation | CBS260-230V | CBS260UL-120V |
Rated Voltage | 200...230 V | 100...120 V |
Power frequency | 50/60 Hz | 50/60 Hz |
Nominal power | 1,5 kW | 1,5 kW |
Unit fuse | 10,0 A | 16,0 A |
Phase (Nominal voltage) | 1~ | 1~ |
Designation | CBS260-230V | CBS260UL-120V |
Interior volume | 9 cu.ft. | 9 cu.ft. |
Net weight of the unit (empty) | 256 lbs | 256 lbs |
Load per rack | 22 lbs | 22 lbs |
Permitted load | 88 lbs | 88 lbs |
Wall clearance back | 3,94 in | 3,94 in |
Wall clearance sidewise | 1,97 in | 1,97 in |
Designation | CBS260-230V | CBS260UL-120V |
Width net | 29.13 in | 29.13 in |
Height net | 40.16 in | 40.16 in |
Depth net | 30.91 in | 30.91 in |
Designation | CBS260-230V | CBS260UL-120V |
Interior width | 24.41 in | 24.41 in |
Interior height | 29.53 in | 29.53 in |
Interior depth | 22.64 in | 22.64 in |
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Designation | CBS260-230V | CBS260UL-120V |
Sound-pressure level | 41 dB(A) | 41 dB(A) |
Energy consumption at 37°C | 55 Wh/h | 55 Wh/h |
Designation | CBS260-230V | CBS260UL-120V |
Number of shelves (std./max.) | 2/8 | 2/8 |