slide 2 of 5
Product image
Product image
Product image
Product image
Product image

Model CB-S 260 | CO2 incubators with hot air sterilization

Benefits
  • Safe – cell cultures receive maximum protection against contamination
  • Reliable – constant well-being conditions for the cells
  • Smart – simple routine cleaning and convenient operation
  • Economical – efficient operation without consumables
Standard Please select Model
  • Please select Model
  • Standard
200...230 V Please select Voltage
  • Please select Voltage
  • 100...120 V
  • 200...230 V

Configure your product with options and accessories and request it directly here.

Product description

The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180°C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO₂ measurements conducted in real time.

Important characteristics

  • Temperature range:

    +6°C above ambient temperature to +50°C

  • Humidity range:

    90 to 95% RH

  • CO₂ control range:

    0 to 20 vol.% CO₂

  • Tried-and-tested anti-contamination concept with 180°C hot air sterilization
  • Humidification system with condensation protection
  • CO2 gas mixing jet with Venturi effect
  • CO2 sensor with infrared technology
  • LCD to display temperature and CO2 along with additional information and alarms
  • Internal data logger, measured values can be read out in open format via USB
  • Tightly fitted inner door made of safety glass
  • Seamless stainless steel inner chamber
  • Perforated shelves, stainless steel
  • Troubleshooting system with visual and acoustic alarms
  • Interfaces:

    Ethernet, USB, zero-voltage alarm contact

  • Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size

Technical specifications

Designation

CBS260-230V

CBS260UL-120V

Article Number9640-00039640-0004
Option modelStandardStandard

Designation

CBS260-230V

CBS260UL-120V

Temperature range+6 °C above ambient temperature to 50 °C+6 °C above ambient temperature to 50 °C
Temperature uniformity at 37°C0.4 ± K0.4 ± K
Temperature fluctuation at 37°C0.1 ± K0.1 ± K
Recovery time after door was opened for 30 s at 37°C8 min8 min

Designation

CBS260-230V

CBS260UL-120V

Humidity range90 ...95 % r.F.90 ...95 % r.F.

Designation

CBS260-230V

CBS260UL-120V

CO₂ range0 ...20 Vol.-% CO₂0 ...20 Vol.-% CO₂
CO₂ measuring technologyIRIR
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂5 min5 min

Designation

CBS260-230V

CBS260UL-120V

Rated Voltage200...230 V100...120 V
Power frequency50/60 Hz50/60 Hz
Nominal power1,5 kW1,5 kW
Unit fuse10,0 A16,0 A
Phase (Nominal voltage)1~1~

Designation

CBS260-230V

CBS260UL-120V

Interior volume9 cu.ft.9 cu.ft.
Net weight of the unit (empty)256 lbs256 lbs
Load per rack22 lbs22 lbs
Permitted load88 lbs88 lbs
Wall clearance back3,94 in3,94 in
Wall clearance sidewise1,97 in1,97 in

Designation

CBS260-230V

CBS260UL-120V

Width net29.13 in29.13 in
Height net40.16 in40.16 in
Depth net30.91 in30.91 in

Designation

CBS260-230V

CBS260UL-120V

Interior width24.41 in24.41 in
Interior height29.53 in29.53 in
Interior depth22.64 in22.64 in
Inner doors11
Unit doors11

Designation

CBS260-230V

CBS260UL-120V

Sound-pressure level41 dB(A)41 dB(A)
Energy consumption at 37°C55 Wh/h55 Wh/h

Designation

CBS260-230V

CBS260UL-120V

Number of shelves (std./max.)2/82/8

Downloads

CO2 incubators

CB-S | CB series

pdf, 1.01 MB

Stacking options for BINDER CO2 incubators

C | CB series

pdf, 158.75 KB

CO₂ incubator (CB series) - Stem cell research into healing musculoskeletal disorders

University of Rochester School of Medicine and Dentistry

pdf, 224.21 KB

CB-S series

pdf, 7.77 MB

Binder Gas Supply Service

Mounting and Operating Instructions

pdf, 7.67 MB

Data Sheet Model CB-S 260

pdf, 429.76 KB

Compare products:

Or add another product.