Model BD 23 | Standard-Incubators with gravity convection
Benefits
- Safe and reproducible incubation even under high batch throughputs in long-term operation
- Disinfection routine at 100 °C
- Stable atmosphere by inner glass door
Product description
The BINDER incubator of the BD series with gravity convection is the specialist in long-term and stable continuous operation. This incubator is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media or microbiological heating.
Important characteristics
- Temperature range: room temperature plus +5 °C to +100 °C
- APT.line™ preheating chamber technology
- Gravity convection
- Adjustable exhaust air flap
- Controller with timer functions
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Stackable
- Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm
- Computer interface: RS 422
Technical specifications
| Data | ||
| Designation | BD023-230V | BD023UL-120V |
| Article Number | 9010-0187 | 9010-0189 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +5 °C above ambient temperature to 100 °C | +5 °C above ambient temperature to 100 °C |
| Temperature uniformity at 37°C | 0.5 ± K | 0.5 ± K |
| Temperature fluctuation at 37°C | 0.2 ± K | 0.2 ± K |
| Heating up time to 37°C | 59 min | 59 min |
| Recovery time after door was opened for 30 s at 37°C | 20 min | 20 min |
| Electrical data | ||
| Rated Voltage | 230 V | 120 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 0,2 kW | 0,2 kW |
| Unit fuse | 12,5 A | 12,5 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 1 cu.ft. | 1 cu.ft. |
| Net weight of the unit (empty) | 60 lbs | 60 lbs |
| Load per rack | 26 lbs | 26 lbs |
| Permitted load | 55 lbs | 55 lbs |
| Wall clearance back | 3,94 in | 3,94 in |
| Wall clearance sidewise | 1,97 in | 1,97 in |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 17.13 in | 17.13 in |
| Height net | 19.49 in | 19.49 in |
| Depth net | 20.47 in | 20.47 in |
| Internal Dimensions | ||
| Interior width | 8.74 in | 8.74 in |
| Interior height | 12.99 in | 12.99 in |
| Interior depth | 10.91 in | 10.91 in |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Energy consumption at 37°C | 11 Wh/h | 11 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/4 | 2/4 |
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - chrome plated
Rack - stainless steel
Shelf, perforated - Stainless steel
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 10 mm, top
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 10 mm, back
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 50 mm, back
Door lock - lockable door handle
Pt 100 temperature sensor - additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)
Sorry, no result could be found. Check the spelling or use a new search term.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.
SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.