Temperature ranges between -70 °C and 180 °C, with the added benefit of natural simulation, are what make the BINDER MKT series so unique. At the same time, this environmental simulation chamber fulfills the very highest precision and performance requirements for cyclical temperature tests.
Important characteristics
- Temperature range: -70 °C to +180 °C
- 4 zero-voltage relay contacts
- APT.line™ preheating chamber technology
- Programmable condensation protection for test material
- Heated viewing window with LED interior lighting
- BINDER Multi Management Software APT-COM™ Basic Edition
- Troubleshooting system with visual and audible alarms
- Intuitive touchscreen controller with time-segment and real-time programming
- Internal data logger, measured values can be read out in open format via USB
- 2 access ports with silicone plugs: 80 mm, left and right
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- 4 castors, two with brakes
- Computer interface: Ethernet
- Adjustable ramp function
- Integrated chart recorder
- Real-time clock
- Door heating
- 1 stainless steel rack
- Inner chamber made of stainless steel
- CFC-free refrigerants R-452A and R-23
- Cooling with cascade compressor cooling unit
Technical specifications
| Data | ||
| Designation | MKT720-400V | MKT720-480V-C |
| Article Number | 9020-0387 | 9020-0365 |
| Option model | Standard | with voltage and frequency converter |
| Performance Data Temperature | ||
| Temperature range | -70...180 °C | -70...180 °C |
| Temperature uniformity dependent on set value | 0.1...2.0 ± K | 0.1...2.0 ± K |
| Temperature fluctuation dependent on set value | 0.1...0.5 ± K | 0.1...0.5 ± K |
| Average heating-up rate according to IEC 60068-3-5 | 4.5 K/min | 4.5 K/min |
| Cooling down time from 180°C to -70°C | 120 min | 120 min |
| Average cooling down time according to IEC 60068-3-5 | 4.0 K/min | 4.0 K/min |
| Electrical data | ||
| Rated Voltage | 400 V | 480 V |
| Power frequency | 50 Hz | 60 Hz |
| Nominal power | 13 kW | 13 kW |
| Unit fuse | 32,0 A | 32,0 A |
| Phase (Nominal voltage) | 3~/N/PE | 3~ |
| Dimensions and weights | ||
| Interior volume | 734 L | 734 L |
| Net weight of the unit (empty) | 610 kg | 610 kg |
| Load per rack | 40 kg | 40 kg |
| Permitted load | 160 kg | 160 kg |
| Wall clearance back | 300 mm | 300 mm |
| Wall clearance sidewise | 200 mm | 200 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 1,580 mm | 1,580 mm |
| Height net | 2,005 mm | 2,005 mm |
| Depth net | 1,140 mm | 1,140 mm |
| Internal Dimensions | ||
| Interior width | 1,200 mm | 1,200 mm |
| Interior height | 1,020 mm | 1,020 mm |
| Interior depth | 600 mm | 600 mm |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 65 dB(A) | 67 dB(A) |
| Energy consumption at 20°C | 1,900 Wh/h | 1,900 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 1/11 | 1/11 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - stainless steel
Rack, reinforced - stainless steel, with fasteners (1 set of 4)
Shelf, perforated - Stainless steel
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Dry-air purge - uncontrolled, incl. connection; for preventing condensation
Notch-type access port - notch-type access port in door, 100 x 35 mm
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 80 mm, right
Access port with silicone plug - 80 mm, left
Access port with silicone plug - 125 mm, right
Access port with silicone plug - 125 mm, left
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 125 mm, top
Access port with silicone plug - 80 mm, top
Access port with silicone plug - 100 mm, right
Access port with silicone plug - 100 mm, left
Door lock - lockable door handle
Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
Leakage test - Testing and logging of the leak-tightness of systems containing hydrofluorocarbons in accordance with Regulation EC842/2006, incl. test book
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity/pressure value, including certificate
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded