slide 2 of 9
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image

Model VDL 115 | Vacuum drying chambers for flammable solvents

Benefits
  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe working thanks to ATEX-compliant safety concept
  • Also option of modular complete system with vacuum pump and pump chamber
Standard Please select Model
  • Please select Model
  • Standard
200...230 V Please select Voltage
  • Please select Voltage
  • 100...120 V
  • 200...230 V

Configure your product with options and accessories and request it directly here.

Product description

BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents. Explosion-protected unit with classification according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X.

Important characteristics

  • Temperature range:

    +9°C above ambient temperature to +110 °C

  • ATEX conformity for units:

    EX II 2/3/- G IIB T3 Gb/Gc/- X

  • Intuitive touchscreen controller with graphical pressure and temperature display
  • Program-controlled drying monitoring with automatic ventilation at end of process
  • Internal data logger, measured values can be read out in open format via USB
  • Pressure control device for heating activated from < 100 mbar
  • 2 aluminum expansion racks, can be custom-positioned
  • Universal connection for ventilation with ambient air or inert gas
  • Universal access port DN 16 - for the introduction of external measuring devices
  • Shatterproof, spring-mounted safety glass panel
  • Large viewing window
  • Computer interface:

    Ethernet

Technical specifications

DesignationVDL115-230V

VDL115-120V

Article Number9630-00119630-0015
Option model

Standard

Standard

DesignationVDL115-230V

VDL115-120V

Temperature range+9 °C above ambient temperature to 110 °C+9 °C above ambient temperature to 110 °C
Temperature uniformity at 100°C2.9 ± K2.9 ± K
Temperature fluctuation at 100°C0.1 ± K0.1 ± K
Heating up time to 100°C170 min170 min

DesignationVDL115-230V

VDL115-120V

Leak rate0,01 bar/h0,01 bar/h
Pressure fluctuation over time at 50 mbar1 ± mbar1 ± mbar
Pressure fluctuation over time at 400 mbar70 ± mbar70 ± mbar

DesignationVDL115-230V

VDL115-120V

Rated Voltage200...230 V100...120 V
Power frequency50/60 Hz50/60 Hz
Nominal power1,6 kW1,6 kW
Unit fuse10,0 A20,0 A
Phase (Nominal voltage)1~1~

DesignationVDL115-230V

VDL115-120V

Vacuum connection with small flange16 DN mm16 DN mm
Measuring access port with small flange16 DN mm16 DN mm

DesignationVDL115-230V

VDL115-120V

Interior volume119 L119 L
Net weight of the unit (empty)158 kg158 kg
Load per rack20 kg20 kg
Permitted load70 kg70 kg
Wall clearance back100 mm100 mm
Wall clearance sidewise70 mm70 mm

DesignationVDL115-230V

VDL115-120V

Width net743 mm743 mm
Height net942 mm942 mm
Depth net581 mm581 mm

DesignationVDL115-230V

VDL115-120V

Interior width506 mm506 mm
Interior height506 mm506 mm
Interior depth460 mm460 mm
Unit doors11

DesignationVDL115-230V

VDL115-120V

Sound-pressure level40 dB(A)40 dB(A)
Energy consumption at 100°C230 Wh/h230 Wh/h

DesignationVDL115-230V

VDL115-120V

Number of shelves (std./max.)2/62/6

Downloads

Vacuum drying chambers

VD | VDL series

pdf, 1.38 MB

Vacuum pump VP5 EX

pdf, 737.99 KB

Vacuum drying chambers (VD | VDL series) - BINDER chambers play a role in smartphone production

GEWO Feinmechanik GmbH

pdf, 258.36 KB

Vacuum drying chambers (VD | VDL series) - How Aesculap uses BINDER chambers for quality testing

B | Braun Aesculap AG

pdf, 180.57 KB

Vacuum drying chambers (VDL series) - Quality testing: Nutriswiss tests oil in BINDER vacuum drying chamber

Nutriswiss AG

pdf, 416.93 KB

VDL series

pdf, 10.72 MB

VP Pump Modules for Vacuum Drying Ovens VD and VDL

pdf, 4.75 MB

Data Sheet Model VDL 115

pdf, 306.53 KB

Compare products:

Or add another product.