Model BD 115 | Standard-Incubators with natural convection
Benefits
- Excellent temporal and spatial temperature accuracy
- High process reliability
- 100°C disinfection routine
Product description
The BD Avantgarde.Line series is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media. The new design of the units and the homogeneous temperature distribution ensure the very best results.
Important characteristics
- Temperature range: +5°C above ambient temperature to +100°C
- High temperature accuracy thanks to APT.line™ technology
- Natural convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Stackable
- Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
- Ergonomic handle design
- USB port for recording data
Technical specifications
| Data | ||
| Designation | BD115-230V | BD115UL-120V |
| Article Number | 9010-0325 | 9010-0326 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +5 °C above ambient temperature to 100 °C | +5 °C above ambient temperature to 100 °C |
| Temperature uniformity at 37°C | 0.3 ± K | 0.3 ± K |
| Temperature uniformity at 100°C | 1.0 ± K | 1.0 ± K |
| Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K |
| Temperature fluctuation at 100°C | 0.3 ± K | 0.3 ± K |
| Heating up time to 100°C | 90 min | 90 min |
| Heating up time to 37°C | 55 min | 55 min |
| Recovery time after door was opened for 30 s at 37°C | 15 min | 15 min |
| Electrical data | ||
| Rated Voltage | 230 V | 120 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 0,35 kW | 0,35 kW |
| Unit fuse | 6,3 A | 12,5 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 112 L | 112 L |
| Net weight of the unit (empty) | 54 kg | 54 kg |
| Load per rack | 30 kg | 30 kg |
| Permitted load | 150 kg | 150 kg |
| Wall clearance back | 160 mm | 160 mm |
| Wall clearance sidewise | 100 mm | 100 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 710 mm | 710 mm |
| Height net | 705 mm | 705 mm |
| Depth net | 605 mm | 605 mm |
| Internal Dimensions | ||
| Interior width | 510 mm | 510 mm |
| Interior height | 530 mm | 530 mm |
| Interior depth | 420 mm | 420 mm |
| Inner doors | 1 | 1 |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Energy consumption at 100°C | 150 Wh/h | 150 Wh/h |
| Energy consumption at 37°C | 25 Wh/h | 25 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/5 | 2/5 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - chrome plated
Rack - stainless steel
Shelf, perforated - Stainless steel
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 10 mm, top
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 10 mm, back
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 50 mm, back
Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display
Door lock - lockable door handle
Sorry, no result could be found. Check the spelling or use a new search term.
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder