Incubators from the APT.line™
KB 23 (E3.1)
Refrigerated incubator with program controller
The KB is the all-rounder for microorganisms. With its wide range of individual programming functions, including a real-time clock function and an enormous temperature span, it can be used for a broad range of sophisticated applications in laboratories – with minimal dehumidification of specimens and impressive extra performance. The APT.line™ with its electronically controlled preheating chamber ensures rapid recovery times and maximum precision, unaffected by the ambient temperature.
- Electronically controlled APT.line™ preheating chamber and patented DCT™ refrigeration system assuring temperature accuracy and reproducible results in both heating and cooling situations
- Temperature range: temperature range 0 °C to 100 °C (32 °F to 212 °F)
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
- Features:
- Integrated week program timer with real time function
- Adjustable ramp function via program editor
- Integrated week program timer with real time function
- Digital temperature setting with an accuracy of a tenth of a degree
- Adjustable fan speed
- Elapsed time indicator
- Independent adjustable temperature safety device, Class 3.1 (DIN 12880) with visual and audible alarm
- Inner glass door
- RS 422 interface for communication software APT-COM™ DataControlSystem, or switch over to printer output with RS 232 / RS 422 interface converter
- Adjustable intervals for printer
- Units up to 115 liters (4.1 cu.ft) are stackable
- 2 stainless steel racks
- BINDER test certificate
|
Based on the ice increase on the evaporators the refrigerating capacity decreases at a set value of < 0 °C (32 °F).
For this reason the chambers have to be defrosted regularly (approx. once a week).
1) at an ambient temperature ≤20 °C (68 °F)
2) up to 98 % of the set value
3) these values can be used upon calculation of air conditioning systems
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.
-
BINDER Data Logger kits
The new BINDER Data Logger kits for temperature and humidity can record temperature and humidity data of BINDER equipment. This finely tuned product solution also contains useful accessories for mounting the Logger on the BINDER unit, including cable bushings and a sensor mounting bracket.
-
Calibration certificates and validation
BINDER can significantly reduce the time and effort needed for equipment qualification and validation. We draw on unparalleled knowledge of our equipment applications and years of experience in certification.
-
Access ports
With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50, 100 mm (0.4, 1.2, 2, 3.94 inch) diameter.
-
Operational data documentation: APT-COM™ DataControlSystem
The only standard software that guarantees seamless documentation of all testing parameters in compliance with standards. Can be fully validated in accordance with GLP/GMP and FDA 21 CFR Part 11.
|
||
| KB 23 (E3.1) | ||
| Access port with silicone plugs, 10 mm (0.39 inch), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) | O | |
| Factory calibration certificate. Measurement in center of chamber at 37 °C (98.6 °F) or at specified testing temperature | O | |
| Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature | O | |
| Temperature measurement acc. to DIN 12880 (15 measuring points) at 37 °C (98.6 °F) or at specified temperature with measuring protocol and certificate | O | |
| Securing elements for additional fastening of racks (1 set of 4 pieces) | O | |
| Anti-slip rubber pads for safe stacking (1 set of 4 pieces) | O | |
| Data Logger Kit T 220: For the continuous temperature recording of -90 °C (-130 °F) to 220 °C (428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit | O | |
| Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable | O | |
| Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller’s controller contacts. Outputs can be switched on and off program-controlled either automatically, or also manually | O | |
| Rack, stainless steel | O | |
| Shelf, perforated, stainless steel | O | |
| Door lock | O |