Environmental test chambers from the APT.line™

MKF series:
Environmental simulation chambers for complex alternating climatic profiles

The MKF series is ideally suited for all tests in accordance with current temperature and climatic test standards based on DIN and IEC standards. The required temperature and humidity values can be attained rapidly and maintained accurately, even under extreme conditions. The unparalleled ease of operation as well as extensive standard features provide that ‘little extra’ in handling.

BINDER Umweltsimulationsschränke

  • Electronically controlled APT.line™ preheating chamber technology
  • Temperature range without humidity -40 °C to +180 °C (-40 °F to +356 °F), with humidity +10 °C to +95 °C (+50 °F to +203 °F)
  • Humidity range 10 % r.H. to 98 % r.H.
  • MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
    • User-friendly LCD screen
    • Easy-to-read menu guide
    • Integrated electronic chart recorder
    • Variety of options for the graphic display of process parameters
    • Real-time clock
  • Electronically controlled humidification and dehumidification system with capacitive humidity sensor
  • Integrated water reservoir for demineralized water
  • Heated viewing window with interior lighting
  • Variable adjustable high-performance fan
  • Programmable condensation protection for test material
  • Adjustable ramp functions via program editor
  • Environmentally friendly refrigerant R 404a
  • 230 V power socket on the right-side operating panel
  • Independent adjustable temperature safety device, Class 2 (DIN 12880)
  • 4 potential-free relay outputs that can be activated via MCS controller
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • Access port, Ø 80 mm (3.1 inch), right side (MKF 240), and right and left sides (MKF 720)
  • 2 stainless steel shelves
  • BINDER test certificate
MKF 240MKF 720
Exterior dimensions  
Width (mm/inch) 1130 / 44.5 1381 / 54.4
Height (inclusive castors) (mm/inch) 1713 / 67.4 1997 / 78.6
Depth, excl. 53 mm (2 inch) for 946 / 37.2 988 / 38.9
door handle (mm/inch)  
Wall clearance (mm/inch) 160 / 6.3 160 / 6.3
Viewing window width (mm/inch) 508 / 20 360 / 14.2
Viewing window height (mm/inch) 300 / 11.8 760 / 29.9
Number of doors 1 1
   
Interior dimensions  
Width (mm/inch) 735 / 28.9 1000 / 39.4
Height (mm/inch) 700 / 27.6 1168 / 46
Depth (mm/inch) 443 / 17.4 600 / 23.6
Interior volume (l/cu.ft.) 228 / 8.1 700 / 25.1
Shelves (number standard/max.) 2 / 6 2 / 14
Load per shelf (kg/lbs.) 30 / 66 30 / 66
Permitted total load (kg/lbs.) 70 / 155 120 / 265
Weight (empty) (kg/lbs.) 360 / 773 540 / 1192
   
Temperature data (without humidity)  
Temperature range (°C / °F) -40* to 180 / -40* to 356 -40* to 180 / -40* to 356
Temperature fluctuation without humidity (± °C)** 0.1 to 0.5 0.1 to 0.4
Temperature variation without humidity (± °C)** 0.5 to 2 0.5 to 2.5
Average heating rate acc. IEC 60068-3-5 (K/min.)* 5 3
Average cooling rate acc. IEC 60068-3-5 (K/min.)* 5 3
Heating up time from -40 °C up to 180 °C (Min.)*** 45 85
Cooling down time from 180 °C up to -40 °C (Min.)*** 98 180
Heat compensation, max. (W)***** 2800 2500
   
Climatical data  
Temperature range (°C/°F) 10 to 95 / 50 to 203 10 to 95 / 50 to 203
Humidity range (% RH) 10 to 98 10 to 98
Humidity fluctuation (± % RH)**/**** 0.5 to 2 0.5 to 2.5
Dew point temperature range (°C) 5 to 94 5 to 94
Heat compensation, max. (W)***** 300 300
   
Electrical data  
Housing protection acc. to EN 60529 IP 20 IP 20
Nominal voltage 50/60 Hz (V) 400 (3N) 400 (3N)
Nominal power (W) 6000 8000
Noise level (ca. dB(A)) 62 65
Individually tested in compliance with VDE 0113 true true
   

1) Temperature range 25 °C to + 95 °C (+ 77 °F to + 203 °F) and < 90 % r.H.
* Valid at an ambient temperature up to 25 °C (+ 77 °F)

All specified technical data apply for standard equipment operating at an ambient temperature of + 25 °C (77 °F), with line voltage fluctuations of ± 10%. These typical average values for series equipment were determined in accordance with the BINDER factory standard. They are based upon the recommended distances from the inner chamber walls, namely 10% of height, width and depth. Differing ambient temperatures or variances in the design of individual equipment may produce different performance data.

We therefore recommend that equipment be calibrated and/or validated on a case-by-case basis when working at the extremes of the permissible ambient temperature range.