Constant climate chambers with light from the APT.line™
KBF LQC 240 (E5.2)
Constant climate chamber with Light Quantum Control (LQC)
Genuine KBF equipment including lighting for compliance with standards, performance and functionality, with expanded photostability test features which we have patented. Two non-directional spherical sensors flexibly capture the available quantity of light at a specific sampling location more realistically than all other systems; in combination with BINDER’s light integration, this is the only method that simulates chemical actinometry electronically in accordance with ICH Q1B.
- Electronically controlled APT.line™ preheating chamber and refrigerating system assuring temperature accuracy and reproducible results
- 2 variable positioned illumination cassettes with BINDER Q1B Synergy Light™ for unique homogenous light distribution in accordance with ICH Q1B guideline, option 2
- Light Quantum Control LQC, precise light intensity measurement, directly at the sample location
- Temperature range 0 °C (32 °F) up to 70 °C (158 °F) - without illumination and humidity
- Temperature range 10 °C (50 °F) up to 60 °C (140 °F) - with illumination and humidity
- Humidity range 10 % to 80 % RH (without illumination)
- Humidity range 10 % to 75 % RH (with illumination)
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- Features:
- User friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A (R2)
- Inner glass door with sealing
- Independent adjustable temperature safety device class 3.1 (DIN 12880), with visual and audible temperature alarm
- Access port with silicone plug Ø 30 mm (1.18 inch), left side
- Safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.)
- Ethernet interface for APT-COM™ DataControlSystem software
- 2 stainless steel racks included
- BINDER test certificate
|
|
We recommend the BINDER Pure Aqua Service for longer maintenance intervals, regardless of water quality. |
|
Demineralized or deionized water available at the customers location. |
1) Lower values are valid up to an ambient temperature of max. 25 °C (77 °F)
2) up to 98 % of the set value
3) Average value, measured with a spherical sensor (±10%) by 12 cm (4.7 inch) below the light cassette
4) Use this value for dimensioning air condition systems
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a voltage fluctuation of ±10 %. The temperature data are determinated in ccordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height,width and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.
-
BINDER Data Logger kits
The new BINDER Data Logger kits for temperature and humidity can record temperature and humidity data of BINDER equipment. This finely tuned product solution also contains useful accessories for mounting the Logger on the BINDER unit, including cable bushings and a sensor mounting bracket.
-
BINDER Pure Aqua Service
Our efficient, flexible water purification system delivers top water quality and extends the maintenance period. Special feature: Our system uses a disposable purification cartridge and also has a water quality indicator.
-
External fresh water supply set
External fresh water supply set consits of fresh and waste water canister, cabling and pump.
-
Specimen temperature measurement
Additional flexible PT 100 temperature sensor for precise temperature measurement of the specimen with digital temperature display. Recording of measured data possible via Ethernet or RS 422 interface.
|
||
| KBF LQC 240 (E5.2) | ||
| Access port with silicone plugs, 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) | O | |
| Securing elements for additional fastening of racks (1 set of 4 pieces) | O | |
| Keyboard lock | O | |
| RS 422 connection for communication software APT - COM™ DataControlSystem | O | |
| Additional PT 100 temperature sensor, flexibly installed, with external connection, including DIN connector (6-pin) | O | |
| Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 °C (77 °F) / 60% RH or at specified values | O | |
| Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values | O | |
| Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 25 °C (77 °F) / 60% RH or at specified values | O | |
| External fresh water supply set consits of fresh and waste water canister, cabling and pump | O | |
| BINDER PURE AQUA SERVICE consisting of disposible cartridge, hose set and measuring unit | O | |
| Disposable cartridge for BINDER PURE AQUA SERVICE | O | |
| External chart recorder for temperature and humidity | ||
| Data Logger Kit TH 70: For the continuous temperature and humidity recording of -40 °C (-40 °F) to 70 °C (158 °F) / 0% to 100 % RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit | O | |
| Data Logger Kit TH 70/70: With two attachable combined sensors. One for the continuous temperature and humidity recording of -40 °C (-40 °F) to 70 °C (158 °F) / 0% to 100 % RH. Second one at the data logger for recording the environmental conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors with 2 m extension cable and 1 fixture for the connection at the BINDER unit | O | |
| Data Logger Kit T 220: For the continuous temperature recording of -90 °C (-130 °F) to 220 °C (428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit | O | |
| Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable | O | |
| Rack, stainless steel | O | |
| Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces) max. load 70 kg (154 lbs.) | O | |
| Shelf, perforated, stainless steel | O | |
| Temperature safety device, Class 3.3 (DIN 12880) with visual alarm | O | |
| 4-20 mA analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6 - pin DIN socket. Outputs are adjusted automatically as the controller is adjusted | O | |
| Zero-voltage relay alarm outputs for temperature (±2 °C) and humidity (±5 % RH), accessible via 6 - pin DIN socket, with acoustic signal that can be switched off (maximum power rating 24 V AC / DC, 2.5 A) | O | |
| Door lock | O | |
| Replacement set illumination tubes for one illumination cassette, including 3 cool white fluorescent tubes and 2 BINDER Q1B Synergy Light™ fluorescent tubes | O |