The BINDER KB series
Refrigerated incubators with forced convection
The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 °C to 100 °C. With its comprehensive program functions, it offers a wide range of capabilities and delivers reproducible test results.
Advantages:
- Safe and reproducible incubation
- Disinfection routine
- Broad range of products and applications
Areas of application:
-
Biotechnology -
Food / Beverage -
Microbiology -
Plant / Insect Growth
| Features | Customer benefits | Characteristics |
|---|---|---|
| APT.line™ |
|
APT.line™ for maximum precision
|
| Disinfection and cleaning |
|
Disinfection routine at 100 °C
|
| Inner chamber concept |
|
High energy efficiency
|
| Cooling system |
|
|
| Control and Documentation |
|
|
| Accessories and Service |
|
Wide range of products
|
- Electronically controlled APT.line™ preheating chamber with DCT™ cooling system assuring temperature accuracy and reproducible results
- Temperature range -5 °C to 100 °C
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
-
Integrated weekly program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of a tenth of a degree
- Adjustable fan speed
- Elapsed time indicator
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Inner glass doors
- RS 422 interface for use with APT-COM™ DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Adjustable intervals for printer
- Access port with silicone plug Ø 30 mm, left side
- 2 shelves, stainless steel
- BINDER test certificate
| KB 720 (E5.1) | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (mm) | 1250 | |
| Height (incl. casters) (mm) | 1925 | |
| Depth (plus door handle, I-panel and connection 52 mm) (mm) | 887 | |
| Wall clearance, rear (mm) | 100 | |
| Wall clearance, side (mm) | 100 | |
| Steam space volume (l) | 918 | |
| Number of doors (ea.) | 2 | |
| Inner glass door(s) (ea.) | 2 | |
|
|
Interior dimensions | |
| Width (mm) | 970 | |
| Height (mm) | 1250 | |
| Depth (mm) | 576 | |
| Interior volume (l) | 698 | |
| Racks (number standard/max.) | 2 / 15 | |
| Load per rack (kg) | 45 | |
| Permitted total load (kg) | 150 | |
| Weight (empty) (kg) | 309 | |
|
|
Temperature data | |
| Temperature range (°C) 1) | -5 - 100 | |
| Temperature variation max. (± C) | 0,5 | |
| at 4 °C (± K) | 0,2 | |
| at 25 °C (± K) | 0,2 | |
| at 37 °C (± K) | 0,2 | |
| Temperature fluctuation max. (± K) | 0,1 | |
| Recovery time after door was opened for 30 sec 2) | ||
| at 4 °C (min.) | 12 | |
| at 37 °C (min.) | 2 | |
|
|
Electrical data | |
| IP protection class acc. to EN 60529 | IP 20 | |
| Voltage (± 10%) 50 / 60 Hz (V) | 200-240 1N~ | |
| Nominal power at 240 V (kW) | 2,3 | |
| Energy consumption 3) | ||
| at 37 °C (W) | 510 | |
| Noise level (dB (A)) | 53 |
1) Lower values are valid up to an ambient temperature of max. 25 °C.
2) To 98% of the set value
3) These values can be used for dimensioning air condition systems.
The useable interior height depends on the position of racks.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
Watertight inner chamber socket
Switched via main switch. For connecting external devices within the chamber.
Additional PT 100 temperature sensor
Fixed or flexible installation with external connection for accurate temperature measurement within the sample material.
Calibration certificate & validation
BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.
BINDER Data Logger Kits
The new BINDER Data Logger Kits – Makes independent recording of temperature data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount.
Operating data documentation: APT-COM™ DataControlSystem
The only standard software that guarantees seamless documentation of all testing parameters in compliance with standards. Can be fully validated in accordance with GLP/GMP and FDA 21 CFR Part 11.
| KB 720 (E5.1) | |
|---|---|
| Access ports with silicone plug, 10, 30, 50, 100 mm | O |
| Fasteners for additional security for racks (1 set of 4) | O |
| Additional PT 100 temperature sensor, flexibly installed with external connection, includes 6-pin DIN socket | O |
| Ethernet interface for communication software APT-COM™ DataControlSystem | O |
| Calibration certificate, measurement in center of chamber at 37 °C or at specified testing temperature | O |
| Extension to calibration certificate. Each additional measurement at additional measuring point or testing temperature | O |
| Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C or at specified temperature with measuring protocol and certificate | O |
| Data Logger Kit T 220: For continuous temperature recording of -90 °C to 220 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit | O |
| Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable | O |
| Rack, stainless steel | O |
| Reinforced rack, stainless steel, with 1 set of fasteners (1 set of 4), max. load 70 kg | O |
| Perforated shelf, stainless steel | O |
| Stable shelf (positioned at bottom shelf level) with additional mounting for shaker operation. Other positions possible on request | O |
| Temperature safety device, class 3.3 (DIN 12880) with visual alarm | O |
| Switchable waterproof interior socket 230 V AC (max. 200 W), Protection class IP 65, with corresponding plug (protection class IP 66). Max. permissible operating temperature 50 °C | O |
| Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable) | O |
| Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller's contacts. Outputs can be switched on and off either automatically and manually | O |
| Door lock | O |