BINDER Environmental simulation chamber - MKFT series
Environmental simulation chamber for low temperature alternating climate profiles
The BINDER MKFT series environmental simulation chamber for low temperature alternating climate profiles is the specialist for dynamic alternating climate change between -70 °C and 180 °C. Large performance reserves and rapid cooling make the MKFT environmental simulation chamber the high-end product for complex standards-based climate tests.
Advantages:
Areas of application:
-
Automotive -
Electronics / Semiconductor Industry -
Aerospace, Defense Industry
| Features | Customer benefits | Characteristics |
|---|---|---|
| APT.line™ climate technology |
|
APT.line™
|
| Humidification system and water supply |
|
Vapor pressure humidification
|
| Standard equipment |
|
Well equipped
|
| Unit design |
|
Good use of space
|
| Production |
|
|
| Accessories and Services |
|
Comprehensive product portfolio
|
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range without humidity: -70 °C to 180 °C
- Temperature range with humidity: 10 °C to 95 °C
- Humidity range 10 % to 98 % RH
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User-friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real-time clock
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor and vapor pressure humidification
- Integrated water storage tank
- Heated viewing window with LED interior lighting
- Programmable condensation protection for test material
- Adjustable ramp function via program editor
- 230 V power socket on the right-side operating panel
- Independent adjustable temperature safety device Class 2
- 4 potential-free relay outputs that can be activated via MCS controller
- Ethernet interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-COM™ DataControlSystem software
- BINDER Communication software APT-COM™ 3 Basic Edition
- Access port Ø 50 mm, left side
- 4 casters (2 with brakes)
- Stainless steel rack included
- BINDER test confirmation
| MKFT 115 | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (mm) | 1000 | |
| Height (incl. castors) (mm) | 1725 | |
| Depth (incl. cable and door handle) (mm) | 915 | |
| Wall clearance rear (mm) | 300 | |
| Wall clearance side (mm) | 200 | |
| Viewing window width (mm) | 288 | |
| Viewing window height (mm) | 222 | |
| Number of doors (ea.) | 1 | |
|
|
Interior dimensions | |
| Width (mm) | 600 | |
| Height (mm) | 480 | |
| Depth (mm) | 400 | |
| Interior volume (l) | 115 | |
| Racks (number standard/max.) | 1 / 4 | |
| Load per shelf (kg) | 30 | |
| Permitted total load (kg) | 60 | |
| Weight (empty) (kg) | 330 | |
|
|
Temperature data | |
| Temperature range (°C) | -70 - 180 | |
| Temperature fluctuation (±K) | 0,1 - 0,5 | |
| Temperature variation (±K) | 0,1 -1,3 | |
| Mean warm-up rate acc. to IEC 60068-3-5 (K/min.) | 5,5 | |
| Mean cooling rate acc. to IEC 60068-3-5 (K/min.) | 4,2 | |
| Max. heat compensation up to 25 °C (W) | 1500 | |
|
|
Climate data | |
| Temperature range (°C) | 10 - 95 | |
| Temperature fluctuation (± K) | 0,1 - 1,0 | |
| Humidity range (% RH) | 10 - 98 | |
| Humidity fluctuation (± % RH) | ≤ 2,5 | |
| Dew point temperature range (°C) | 5 - 94 | |
| Max. heat compensation to 25 °C / 90 % RH (W) | 400 | |
|
|
Electrical data | |
| IP protection class acc. to EN 60529 | IP 20 | |
| Voltage (± 10%) 50 Hz (V) | 400 3N~ | |
| Nominal power (kW) | 6,2 | |
| Energy consumption 25 °C / 60 % RH (Wh/h) 1) | 1250 | |
| Noise level approx. (dB (A)) | 62 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
BINDER PURE AQUA SERVICE
This convenient and flexible water treatment system extends maintenance intervals and is easily implemented independent of water quality.
The specific advantage: Point-of-use system with water quality display and replaceable filter cartridge.
Notch-type access port in door
Provides easy connection of cables to test specimens and facilitates loading and unloading of the chamber. Doors have access ports measuring 100 x 35 mm, which can be sealed with the included silicone plugs.
Temperature measurement of the specimen
Additional measuring channel for digital display of specimen temperature, with flexible PT 100 temperature sensor. Measuring data recorded through device interface.
BINDER Data Logger Kits
The new BINDER Data Logger Kits – Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount.
Reinforced racks
To ensure safe and stable storage of heavy test specimens.
| MKFT 115 | |
|---|---|
| Access ports with silicone plug, 30, 50, 80, 100, 125 mm | O |
| Securing elements for additional fastening of racks (1 set of 4) | O |
| Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable) | O |
| Door lock | O |
| Additional measuring channel for digital display of specimen temperature with flexible PT 100 temperature sensor. Measuring data recorded through device interface | O |
| Temperature safety device for over and under temperature, Class 2 | O |
| RS 422 interface | O |
| Temperature measurement acc. to DIN 12880-2 and 9-point humidity measurement/factory standard with protocol and certificate at 25 °C / 60% RH or at specified values | O |
| Calibration certificate for temperature and humidity. Measurement in center of chamber at 25 °C / 60% RH or at specified values | O |
| Extension to calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values | O |
| BINDER PURE AQUA SERVICE containing single-use cartridge, cabling, and pump | O |
| Single-use cartridge for BINDER PURE AQUA SERVICE | O |
| Water circle, possibility to reuse water | O |
| Data Logger Kit TH 100/70: With two attachable combined sensors for temperature and humidity recording | O |
| Data Logger Kit TH 100: With one attachable combined sensor for temperature and humidity recording | O |
| Data Logger Kit TH 220: With PT 100 sensor for temperature recording | O |
| Data Logger Software | O |
| Data Logger converter cable (RS 232 to USB 2.0) | O |
| Rack, stainless steel | O |
| Reinforced rack, stainless steel, with 1 set of fasteners (4 pieces), max. load 70 kg | O |
| Shelf perforated, stainless steel | O |
| Notch-type access port in door, 100 x 35 mm | O |