The BINDER KMF series
Constant climate chamber for stress testing from -10 °C to 100 °C
The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant climate chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this constant climate chamber ideally suited for stress testing series.
Advantages:
- The only one in its class
- Stable test conditions up to 85 °C / 85% RH
- Optimal ratio of usable space and footprint
Areas of application:
-
Automotive -
Plastics Industry -
Packaging Industry
| Features | Customer benefits | Characteristics |
|---|---|---|
| APT.line™ climate technology |
|
APT.line™
|
| Water supply |
|
|
| Humidification system |
|
|
| Cooling system |
|
|
| Standard equipment |
|
Comprehensive standards
|
| Unit design |
|
|
| Production |
|
|
| Accessories and Services |
|
Comprehensive product portfolio
|
- Electronically controlled APT.line™ preheating chamber and refrigerating system assuring temperature accuracy and long term stable reproducible results
- Temperature range -10 °C to 100 °C (without humidity)
- Temperature range 10 °C to 90 °C (with humidity)
- Humidity range 10 % to 90 % RH
-
MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor
- Heated door
- Inner glass door with sealing
- Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
- Access port with silicone plug Ø 30 mm, left side
- Safety connection kit for water supply and drainage, including water hose, total length 6 m
- Ethernet interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-COM™ DataControlSystem software
- BINDER Communication software APT-COM™ 3 Basic Edition
- Stainless steel rack
- BINDER test confirmation
| KMF 115 (E5.2) | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (mm) | 885 | |
| Height (incl. feet) (mm) | 1050 | |
| Depth (plus door handle, I-panel, connection 80 mm) (mm) | 650 | |
| Wall clearance, rear (mm) | 100 | |
| Wall clearance, side (mm) | 100 | |
| Number of doors (ea.) | 1 | |
| Inner glass door(s) (ea.) | 1 | |
|
|
Interior dimensions | |
| Width (mm) | 600 | |
| Height (mm) | 483 | |
| Depth (mm) | 351 | |
| Interior volume (l) | 102 | |
| Racks (number standard/max.) | 1 / 5 | |
| Load per rack (kg) | 30 | |
| Permitted total load (kg) | 100 | |
| Weight (empty) (kg) | 127 | |
|
|
Technical data in temperature mode (without humidity) | |
| Temperature range (°C) | -10 - 100 | |
| Mean warm-up rate acc. to IEC 60068-3-5 (K/min.) | 1,3 | |
| Mean cooling rate acc. to IEC 60068-3-5 (K/min.) | 0,5 | |
| Warm-up time from -10 °C to 100 °C (min.) | 85 | |
| Cooling down time from 100 °C to -10 °C (min.) | 240 | |
| Max. heat compensation up to 25 °C (W) | 150 | |
|
|
Technical data in climate mode (with humidity) | |
| Temperature range (°C) | 10 - 90 | |
| Temperature variation (±K) | 0,3 - 1,0 | |
| Temperature fluctuation (±K) | 0,1 - 0,2 | |
| Humidity range (% RH) | 10 - 90 | |
| Humidity fluctuation (± RH %) | ≤ 2,5 | |
| Dew point temperature range (°C) | 5 - 80 | |
| Max. heat compensation at 25 °C / 90 % RH (W) | 30 | |
|
|
Electrical data | |
| IP protection class acc. to EN 60529 | IP 20 | |
| Voltage (± 10 %) 50 / 60 Hz (V) | 200 - 240, 1 N ~ | |
| Nominal power (kW) | 2,0 | |
| Energy consumption at 85 °C / 85 % RH (W) 1) | 570 | |
| Noise level (dB (A)) | 52 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. Technical data refers to 100% fan speed. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
BINDER Pure Aqua Service
This convenient and flexible water treatment system extends maintenance intervals and is easily implemented independent of water quality.
The specific advantage: Point-of-use system with water quality display and replaceable filter cartridge
BINDER Data Logger Kits
The new BINDER Data Logger Kits – Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount
External water supply set
External water supply set from fresh and waste water container, wiring and pump
APT-COM™ DataControlSystem GLP Edition
Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements
Access port
With silicone plugs for introducing external measuring instruments into the chamber, access ports with 30, 50 or 100 mm diameters
Calibration certificate & validation
BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do
Temperature measurement of the specimen
Additional PT 100 temperature sensor for accurate temperature measurement of the specimen and digital display of measured values. Recording of measured data via Ethernet or RS 422 interface optional
| KMF 115 (E5.2) | |
|---|---|
| Access ports with silicone plug 30, 50, 100 mm | O |
| Securing elements for additional fastening of racks (1 set of 4) | O |
| Additional PT 100 temperature sensor, flexibly installed, with external connection, including LEMO connector (3-pin) | O |
| RS 422 interface | O |
| External fresh water supply set consits of fresh and waste water canister, cabling and pump | O |
| BINDER PURE AQUA SERVICE consisting of disposable cartridge, hose set and measuring unit | O |
| Disposable cartridge for BINDER PURE AQUA SERVICE | O |
| Keyboard lock | O |
| Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 25 °C (77 °F) / 60 % RH or at specified values | O |
| Calibration certificate for temperature and humidity. Measurement in the center at 25 °C (77 °F) / 60 % RH or at specified values | O |
| Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values | O |
| Data Logger Kit TH 100/70: With two attachable combined sensors. One for the continuous temperature and humidity recording of -40 °C to 100 °C / 0 % to 100 % RH. Second one at the data logger for recording the environmental conditions of -40 °C to 70 °C / 0 % to 100 % RH. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors with 2 m extension cable and 1 fixture for the connection at the BINDER unit | O |
| Data Logger Kit TH 100: For the continuous temperature and humidity recording of -40 °C to 100 °C / 0 % to 100 % RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit | O |
| Data Logger Kit T 220: For the continuous temperature recording of -90 °C to 220 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit | O |
| Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) | O |
| Data Logger converter cable (RS 232 to USB 2.0) | O |
| Rack, stainless steel | O |
| Shelf, perforated, stainless steel | O |
| Interior lighting (15 W) | O |
| Locking door handle with key | O |
| Temperature safety device, class 3.3 (DIN 12880) with visual alarm | O |
| 4-20 mA analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6-pin DIN socket. Outputs are adjusted automatically as the controller is adjusted | O |