The BINDER KBW series
Climate chambers with illumination
The BINDER KBW series climate chamber with illumination achieves homogeneous light distribution and ensures consistent temperature conditions with its natural illumination.
Advantages:
- Homogeneous light distribution
- Natural growth conditions
- Temperature, humidity & light in one unit
Areas of application:
-
Cosmetics Industry -
Plant / Insect Growth -
Packaging Industry
| Features | Customer benefits | Characteristics |
|---|---|---|
| APT.line™ climate technology |
|
APT.line™
|
| Light |
|
|
| Cooling system |
|
|
| Standard equipment |
|
Comprehensive standards
|
| Unit design |
|
|
| Accessories and Services |
|
Comprehensive product portfolio
|
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range 0 °C to 70 °C (without illumination)
- Temperature range 5 °C to 60 °C (with illumination)
- 2 variable position illumination cassettes each with 5 daylight fluorescent illumination tubes
- Patented light system for unique homogeneous light distribution over the entire usable area
- 2 racks, stainless steel
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
-
Integrated weekly program timer with real-time function for programming day/night cycles
- Digital temperature setting with an accuracy of a tenth of a degree
- Adjustable ramp function via program editor
- Adjustable fan speed
- Elapsed time indicator
- Access port Ø 30 mm, left side
- Inner glass door
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- RS 422 interface for use with APT-COM™ DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Adjustable intervals for printer
- BINDER test certificate
| KBW 240 (E5.1) | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (mm) | 925 | |
| Height (incl. casters) (mm) | 1460 | |
| Depth (incl. door handle, I-panel, connection) (mm) | 850 | |
| Wall clearance, rear (mm) | 100 | |
| Wall clearance, side (mm) | 100 | |
| Steam space volume (l) | 348 | |
| Number of doors (ea.) | 1 | |
| Inner glass door(s) (ea.) | 1 | |
|
|
Interior dimensions | |
| Width (mm) | 650 | |
| Height (mm) | 785 | |
| Depth (mm) | 485 | |
| Interior volume (l) | 247 | |
| Racks (number standard/max.) | 2 / 9 | |
| Load per rack (kg) | 30 | |
| Permitted total load (kg) | 100 | |
| Weight (empty) (kg) | 202 | |
| Variable position illumination cassettes | 2 | |
|
|
Temperature data (without illumination) | |
| Temperature range (°C) | 0 - 70 | |
| Temperature variation (± K) | 0,5 | |
| Temperature fluctuation (± K) | 0,1 | |
| Max. heat compensation up to 40 °C (W) | 350 | |
|
|
Temperature data (with 100% illumination) | |
| Temperature range (°C) | 5 - 60 | |
| Temperature variation (± K) | 0,5 | |
| Temperature fluctuation (± K) | 0,1 | |
| Max. heat compensation up to 40 °C (W) | 250 | |
| Illumination data (per illumination cassette) | ||
| Daylight tubes (Lux) / (W/m2) | 10.000 / 36 | |
| Fluora® growth lamps (Lux) / (W/m2) | 6.500 / 34 | |
| Arabidopsis tubes (Lux) / (W/m2) | 10.000 / 40 | |
|
|
Electrical data | |
| IP protection class acc. to EN 60529 | IP 20 | |
| Voltage (± 10%) 50 / 60 Hz (V) | 200-240 1N~ | |
| Nominal power (kW) | 1,4 | |
| Energy consumption 1) | ||
| without illumination at 0 °C (W) | 360 | |
| with illumination at 4 °C (W) | 520 | |
| with illumination at 25 °C (W) | 495 | |
| with illumination at 37 °C (W) | 525 | |
| Noise level db (A) | 52 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
Variable illumination
The illumination selection is based on the application, light spectrum and intensity. For example: FLUORA® growth fluorescent tubes may be exchanged for daylight fluorescent tubes
Analog output
Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable)
BINDER DataLogger Kits
The new BINDER Data Logger Kits – Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount.
| KBW 240 (E5.1) | |
|---|---|
| Access ports with silicone plug, 30, 50, 100 mm | O |
| Fasteners for additional security for racks (1 set of 4) | O |
| Additional PT 100 temperature sensor, flexibly installed with external connection, includes 6-pin DIN socket | O |
| Ethernet interface for communication software APT-COM™ DataControlSystem | O |
| Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C or at specified temperature with measuring protocol and certificate | O |
| Calibration certificate, measurement in center of chamber at 37 °C or at specified testing temperature | O |
| Extension to calibration certificate. Each additional measurement at additional measuring point or testing temperature | O |
| Data Logger Kit T 220: For continuous temperature recording of -90 °C to 220 °C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for mounting to the BINDER unit | O |
| Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable | O |
| Rack, stainless steel | O |
| Perforated shelf, stainless steel | O |
| Reinforced rack, stainless steel, with 1 set of fasteners (1 set of 4), max. load 70 kg | O |
| Stable shelf (positioned at bottom shelf level) with additional mounting for shaker operation. Other positions possible on request | O |
| Independent temperature safety device class 3.3 (DIN 12880) with optical alarm | O |
| Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable) | O |
| Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 2 relay outputs via 2 of the programmable controller's contacts. Zero-voltage relay outputs can be switched on and off either automatically and manually | O |
| FLUORA® growth fluorescent tube set for replacing the daylight fluorescent tubes | O |
| Arabidopsis fluorescent tube set for replacing the daylight fluorescent tubes | O |
| Replacement fluorescent tube set for one illumination cassette | O |
| Replacement FLUORA® illumination tube set for one illumination cassette | O |
| Replacement Arabidopsis lamp set for one illumination cassette | O |
| Door lock | O |