Just register your serial number – and enjoy the benefits.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model BF 56 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
BF056-230V | 9010-0313 | + | |||
120 V 1~ 60 Hz | ||||||
Standard |
BF056UL-120V | 9010-0314 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8012-1164 | + | ||||
top |
8012-1150 | + | ||||
top |
8012-1159 | + | ||||
left |
8012-1274 | + | ||||
right |
8012-1162 | + | ||||
top |
8012-1166 | + | ||||
top |
8012-1261 | + | ||||
left |
8012-1156 | + | ||||
right |
8012-1267 | + | ||||
right |
8012-1153 | + | ||||
Alarm function for overheating | ||||||
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device |
8012-1634 | + | ||||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1622 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1111 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1569 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1590 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-1130 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1548 | + | ||||
Clock | ||||||
battery-backed |
8012-1639 | + | ||||
Door lock | ||||||
lockable door handle |
8012-1663 | + | ||||
Ethernet interface | ||||||
for Multi Management Software APT-COM™ |
8012-0990 | + | ||||
Gas-tight option model | ||||||
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1044 | + | ||||
Inert gas connection | ||||||
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1047 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1618 | + | ||||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
Rack | ||||||
|
8012-2085 | + | ||||
|
8012-2038 | + | ||||
Rubber pads | ||||||
set anti-slip feet |
8012-2030 | + | ||||
Shelf, perforated | ||||||
|
6004-0182 | + | ||||
Table on castors | ||||||
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm |
9051-0018 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL40-0100 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate |
DL20-0910 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0200 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0810 | + | |||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | + | |||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0010 | + |
Designation |
BF056UL-120V¹ |
BF056-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0314 | 9010-0313 |
Data | ||
Serie | BF | BF |
Performance Data Temperature | ||
Heating-up time to 37 °C [min] | 6 | 6 |
Recovery time after 30 seconds door open at 37 °C [min] | 3 | 3 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +7 °C above ambient temperature to [°C] | 100 | 100 |
Temperature variation at 37 °C [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 0.4 | 0.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 60 | 50/60 |
Rated Voltage [V] | 120 | 230 |
Unit fuse [A] | 12.5 | 6.3 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 565 | 565 |
Height net [mm] | 625 | 625 |
Width net [mm] | 560 | 560 |
Internal Dimensions | ||
Depth [mm] | 340 | 340 |
Height [mm] | 440 | 440 |
Width [mm] | 400 | 400 |
Measures | ||
Interior volume [L] | 59 | 59 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 40 | 40 |
Permitted load [kg] | 70 | 70 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Heating-up time to 37 °C [min] | 6 | 6 |
Recovery time after 30 seconds door open at 37 °C [min] | 3 | 3 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +7 °C above ambient temperature to [°C] | 100 | 100 |
Temperature variation at 37 °C [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 0.4 | 0.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 60 | 50/60 |
Rated Voltage [V] | 120 | 230 |
Unit fuse [A] | 12.5 | 6.3 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 22.26 | 22.26 |
Height net [in] | 24.63 | 24.63 |
Width net [in] | 22.06 | 22.06 |
Internal Dimensions | ||
Depth [in] | 13.4 | 13.4 |
Height [in] | 17.34 | 17.34 |
Width [in] | 15.76 | 15.76 |
Measures | ||
Interior volume [cu.ft.] | 2.1 | 2.1 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 88 | 88 |
Permitted load [lbs] | 154 | 154 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
BF 56 |
PDF (133.44 kB ) | > |
BF 56 US version with imperial values |
PDF (131.83 kB) | > | |
Operating Manuals |
BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720 |
PDF (10.79 MB) | > |
Technical Drawings |
Version BF 56 Interior dimensions |
PDF (181.48 kB) | > |
Technical Drawings |
Version BF 56 External dimensions |
PDF (190.33 kB) | > |
Technical Drawings |
Version BF 56 Access ports |
PDF (99.88 kB) | > |
Technical Drawings |
Version BF 56 Access ports BINDER INDIVIDUAL |
PDF (92.66 kB) | > |
Case Studies |
Standard incubators (BD series) - Eternal youth with new anti-wrinkle cream Princess Dr. med. Sarah von Isenburg |
PDF (762.42 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Brochures |
Standard-Incubators B | BD | BD-S | BF series |
PDF (1.58 MB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |