Benefits
Important characteristics
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model KBF 720 | ||||||
200…240 V 1~ 50/60 Hz | ||||||
Standard |
KBF720UL-240V | 9020-0325 | + | |||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
KBF720-230V | 9020-0324 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8012-0515 | + | ||||
right |
8012-1466 | + | ||||
left |
8012-1442 | + | ||||
top |
8012-1454 | + | ||||
top |
8012-1460 | + | ||||
right |
8012-1436 | + | ||||
left |
8012-1472 | + | ||||
right |
8012-0514 | + | ||||
top |
8012-1448 | + | ||||
Alarm output, zero-voltage | ||||||
for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off |
8012-1810 | + | ||||
BINDER PURE AQUA SERVICE | ||||||
System for preparation or complete desalination of tap water, complete set containing PURE AQUA 300 single-use cartridge, measuring device, and all necessary connecting parts |
8012-0759 | + | ||||
BINDER PURE AQUA SERVICE, accessories | ||||||
Single-use, replacement cartridge for BINDER PURE AQUA System |
6011-0165 | + | ||||
Calibration certificate, expanded | ||||||
for temperature and humidity; for extending the measurement in center of chamber to include another test value |
8012-0155 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-0917 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-0923 | + | ||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-0920 | + | ||||
Calibration certificate, temperature and humidity | ||||||
Measurement in center of chamber at 25 °C / 60% RH or at specified test values |
8012-0154 | + | ||||
temperature (according to DIN12880) and humidity measurement incl. certificate, 27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 % RH or at specified values |
8012-0924 | + | ||||
Class 3.3 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1034 | + | ||||
Converter, voltage | ||||||
to operate the device at a nominal voltage of 120 V 1 ph 60 Hz |
8009-0821 | + | ||||
Door lock | ||||||
lockable door handle |
8012-1024 | + | ||||
LED light bars | ||||||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1717 | + | ||||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1718 | + | ||||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1716 | + | ||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1108 | + | ||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1107 | + | ||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1109 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1042 | + | ||||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values |
7057-0002 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values |
7007-0002 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values |
7057-0006 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values |
7007-0006 | + | ||||
Rack | ||||||
|
8012-2051 | + | ||||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | + | ||||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0674 | + | ||||
RS 485 / RS 422 interface converter | ||||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0589 | + | ||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0599 | + | ||||
RS 485 interface, 2-wire | ||||||
Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™ |
8012-1066 | + | ||||
Shelf, perforated | ||||||
|
8009-0486 | + | ||||
Shelf, reinforced | ||||||
positioned at bottom level, max. load 45 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system |
8012-1489 | + | ||||
Water supply set | ||||||
consisting of fresh- and waste-water containers (20 liters each), cabling and pump |
8012-1846 | + | ||||
consisting of fresh- and waste-water containers (20 liters each), cabling and pump |
8012-0643 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL42-0300 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity value, including certificate |
DL20-0920 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature and humidity calibration |
Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate |
DL30-0301 | + | |||
Temperature and humidity calibration |
Expansion –Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate |
DL30-0302 | + | |||
Temperature and humidity measurement according to DIN12880 |
Temperature measurement in accordance with DIN 12880 with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0427 | + | |||
Temperature measurement, 18 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 18 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0318 | + | |||
Temperature measurement, 27 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0327 | + | |||
Temperature measurement, 9 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 9 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0309 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0300 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0700 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0030 | + |
Designation |
KBF720UL-240V¹ |
KBF720-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9020-0325 | 9020-0324 |
Data | ||
Serie | KBF | KBF |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 600 | 600 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.2 | 0.2 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | 1,5 ± % RH | 1,5 ± % RH |
Humidity fluctuation at 40 °C and 75 % RH | 1,5 ± % RH | 1,5 ± % RH |
Humidity range | 10…80 | 10…80 |
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] | 16 | 16 |
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] | 17 | 17 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.2 | 0.2 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 3.1 | 3.1 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 200…230 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Inner doors | 2 | 2 |
Unit doors | 2 | 2 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 890 | 890 |
Height net [mm] | 1925 | 1925 |
Width net [mm] | 1250 | 1250 |
Internal Dimensions | ||
Depth [mm] | 576 | 576 |
Height [mm] | 1250 | 1250 |
Width [mm] | 973 | 973 |
Measures | ||
Interior volume [L] | 700 | 700 |
Load per rack [kg] | 45 | 45 |
Net weight of the unit (empty) [kg] | 312 | 312 |
Permitted load [kg] | 150 | 150 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 300 | 300 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 620 | 620 |
Sound-pressure level [dB(A)] | 53 | 53 |
Fixtures | ||
Number of shelves (std./max.) | 2/15 | 2/15 |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 600 | 600 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.2 | 0.2 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | 1,5 ± % RH | 1,5 ± % RH |
Humidity fluctuation at 40 °C and 75 % RH | 1,5 ± % RH | 1,5 ± % RH |
Humidity range | 10…80 | 10…80 |
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] | 16 | 16 |
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] | 17 | 17 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.2 | 0.2 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 3.1 | 3.1 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 200…230 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Inner doors | 2 | 2 |
Unit doors | 2 | 2 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 35.07 | 35.07 |
Height net [in] | 75.8 | 75.8 |
Width net [in] | 49.3 | 49.3 |
Internal Dimensions | ||
Depth [in] | 22.69 | 22.69 |
Height [in] | 49.3 | 49.3 |
Width [in] | 38.34 | 38.34 |
Measures | ||
Interior volume [cu.ft.] | 24.7 | 24.7 |
Load per rack [lbs] | 99 | 99 |
Net weight of the unit (empty) [lbs] | 688 | 688 |
Permitted load [lbs] | 331 | 331 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 11.82 | 11.82 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 620 | 620 |
Sound-pressure level [dB(A)] | 53 | 53 |
Fixtures | ||
Number of shelves (std./max.) | 2/15 | 2/15 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
KBF 720 |
PDF (185.17 kB ) | > |
KBF 720 US version with imperial values |
PDF (185.63 kB) | > | |
Operating Manuals |
KBF | KMF series |
PDF (9.73 MB) | > |
Technical Drawings |
Version KBF 720 External dimensions |
PDF (176.65 kB) | > |
Technical Drawings |
Version KBF 720 Access ports |
PDF (155.96 kB) | > |
Case Studies |
Constant climate chambers (KBF series) - Putting labels through their paces in BINDER chambers Schreiner Group GmbH & Co. KG |
PDF (189.40 kB) | > |
Case Studies |
Constant climate chambers (KBF series) - Test the service life of surgical instruments Aesculap AG |
PDF (187.78 kB) | > |
Case Studies |
Constant climate chambers (KBF LQC series) - Top-quality dairy products Arla Foods Deutschland GmbH |
PDF (802.53 kB) | > |
Case Studies |
Constant climate chambers (KBF series) - Quality testing made quick and easy B | Braun Aesculap AG |
PDF (144.08 kB) | > |
Case Studies |
Constant climate chambers (KBF series) - Desiccants – the all-round talent against corrosion damage TROPACK Packmittel GmbH |
PDF (1.64 MB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.52 kB) | > |
White paper |
Trends in consumer behavior How has the food industry changed in industrialized countries? |
PDF (157.03 kB) | > |
White paper |
Accelerated Shelf-life Testing Of Natural Colours in Model Food Systems |
PDF (765.50 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Options & Accessories |
PURE AQUA SERVICE Serie KBF| KBF P | KBF LQC | KMF | KBWF | MKF | MKFT |
PDF (335.95 kB) | > |
Options & Accessories |
Water supply systems Constant climate chambers |
PDF (137.25 kB) | > |
Options & Accessories |
LED light bar sets Series KB | KT | KBF |
PDF (291.69 kB) | > |
Brochures |
Humidity test chambers KBF | KBF-S | KBF P | KBF LQC | KMF series |
PDF (1.71 MB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |