Just register your serial number – and enjoy the benefits.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model KBF-S 115 | ||||||
200…240 V 1~ 50/60 Hz | ||||||
Standard |
KBFS115UL-240V | 9020-0371 | + | |||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
KBFS115-230V | 9020-0370 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-2078 | + | ||||
top |
8012-2075 | + | ||||
top |
8012-2073 | + | ||||
left |
8012-2072 | + | ||||
right |
8012-2071 | + | ||||
top |
8012-2074 | + | ||||
left |
8012-2079 | + | ||||
left |
8012-2077 | + | ||||
right |
8012-2076 | + | ||||
BINDER PURE AQUA SERVICE | ||||||
System for preparation or complete desalination of tap water, complete set containing PURE AQUA 300 single-use cartridge, measuring device, and all necessary connecting parts |
8012-0759 | + | ||||
BINDER PURE AQUA SERVICE, accessories | ||||||
Single-use, replacement cartridge for BINDER PURE AQUA System |
6011-0165 | + | ||||
Calibration certificate, expanded | ||||||
for temperature and humidity; for extending the measurement in center of chamber to include another test value |
8012-2066 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-2067 | + | ||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-2068 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-2069 | + | ||||
Calibration certificate, temperature and humidity | ||||||
Measurement in center of chamber at 25 °C / 60% RH or at specified test values |
8012-2065 | + | ||||
temperature (according to DIN12880) and humidity measurement incl. certificate, 27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 % RH or at specified values |
8012-2070 | + | ||||
Convenient water supply | ||||||
Flexible positioning of the water container with magnetic holder, hose adapter for water container with practical quick coupling, and water stop function |
8012-1847 | + | ||||
Door lock | ||||||
lockable door handle |
8012-2086 | + | ||||
LED light bars | ||||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1108 | + | ||||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1716 | + | ||||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1717 | + | ||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1107 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values |
7007-0002 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values |
7057-0002 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values |
7007-0006 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values |
7057-0006 | + | ||||
Rack | ||||||
|
8012-2049 | + | ||||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | + | ||||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0700 | + | ||||
Shelf, perforated | ||||||
|
6004-0115 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL42-0300 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity value, including certificate |
DL20-0920 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature and humidity calibration |
Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate |
DL30-0301 | + | |||
Temperature and humidity calibration |
Expansion –Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate |
DL30-0302 | + | |||
Temperature and humidity measurement according to DIN12880 |
Temperature measurement in accordance with DIN 12880 with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0427 | + | |||
Temperature measurement, 18 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 18 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0318 | + | |||
Temperature measurement, 27 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0327 | + | |||
Temperature measurement, 9 temperature measuring points and 1 humidity measuring point |
Temperature measurement with 9 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate |
DL30-0309 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0300 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0700 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0030 | + |
Designation |
KBFS115UL-240V¹ |
KBFS115-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9020-0371 | 9020-0370 |
Data | ||
Serie | KBF-S | KBF-S |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 200 | 200 |
Temperature range | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.3 | 0.3 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | 2,0 % RH | 2,0 % RH |
Humidity fluctuation at 40 °C and 75 % RH | 2,0 % RH | 2,0 % RH |
Humidity range | 20…80 | 20…80 |
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] | 6 | 6 |
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] | 7 | 7 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.3 | 0.3 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.3 | 0.3 |
Electrical data | ||
Nominal power [kW] | 1.4 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 200…230 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 650 | 650 |
Height net [mm] | 1050 | 1050 |
Width net [mm] | 880 | 880 |
Internal Dimensions | ||
Depth [mm] | 351 | 351 |
Height [mm] | 483 | 483 |
Width [mm] | 600 | 600 |
Measures | ||
Interior volume [L] | 102 | 102 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 128 | 128 |
Permitted load [kg] | 100 | 100 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 400 | 400 |
Sound-pressure level [dB(A)] | 52 | 52 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 200 | 200 |
Temperature range | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.3 | 0.3 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | 2,0 % RH | 2,0 % RH |
Humidity fluctuation at 40 °C and 75 % RH | 2,0 % RH | 2,0 % RH |
Humidity range | 20…80 | 20…80 |
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] | 6 | 6 |
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] | 7 | 7 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.3 | 0.3 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.3 | 0.3 |
Electrical data | ||
Nominal power [kW] | 1.4 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 200…230 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 25.61 | 25.61 |
Height net [in] | 41.4 | 41.4 |
Width net [in] | 34.67 | 34.67 |
Internal Dimensions | ||
Depth [in] | 13.83 | 13.83 |
Height [in] | 19.03 | 19.03 |
Width [in] | 23.64 | 23.64 |
Measures | ||
Interior volume [cu.ft.] | 3.6 | 3.6 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 282 | 282 |
Permitted load [lbs] | 220 | 220 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 400 | 400 |
Sound-pressure level [dB(A)] | 52 | 52 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
KBF-S 115 |
PDF (152.59 kB ) | > |
KBF-S 115 US version with imperial values |
PDF (152.23 kB) | > | |
Operating Manuals |
KBF-S series |
PDF (6.92 MB) | > |
Technical Drawings |
Version KBF-S115-230V 9020-0370 |
PDF (469.29 kB) | > |
Technical Drawings |
Version KBF-S115-200-240V 9020-0371 |
PDF (429.65 kB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.52 kB) | > |
White paper |
Trends in consumer behavior How has the food industry changed in industrialized countries? |
PDF (157.03 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Options & Accessories |
PURE AQUA SERVICE Serie KBF| KBF P | KBF LQC | KMF | KBWF | MKF | MKFT |
PDF (335.95 kB) | > |
Options & Accessories |
Water supply systems Constant climate chambers |
PDF (137.25 kB) | > |
Brochures |
Humidity test chambers KBF | KBF-S | KBF P | KBF LQC | KMF series |
PDF (1.71 MB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |