Just register your serial number – and enjoy the benefits.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model MKT 720 | ||||||
480 V 3~ 60 Hz | ||||||
Standard |
MKT720-480V-C | 9020-0365 | + | |||
400 V 3~ 50 Hz | ||||||
Standard |
MKT720-400V | 9020-0387 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-1541 | + | ||||
left |
8012-1324 | + | ||||
right |
8012-1333 | + | ||||
top |
8012-1535 | + | ||||
right |
8012-1350 | + | ||||
right |
8012-1321 | + | ||||
top |
8012-1532 | + | ||||
left |
8012-1353 | + | ||||
left |
8012-1336 | + | ||||
top |
8012-1538 | + | ||||
left |
8012-1544 | + | ||||
left |
8012-1330 | + | ||||
right |
8012-1327 | + | ||||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1785 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1125 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1582 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1603 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-1144 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1561 | + | ||||
Compressed air connection | ||||||
for the connection to an existing pressurized air network |
8012-1800 | + | ||||
Door lock | ||||||
lockable door handle |
8012-1784 | + | ||||
Dry-air purge | ||||||
uncontrolled, incl. connection; for preventing condensation |
8012-1868 | + | ||||
Notch-type access port | ||||||
notch-type access port in door, 100 x 35 mm |
8012-1858 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1790 | + | ||||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
Rack | ||||||
|
8012-2054 | + | ||||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | + | ||||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0684 | + | ||||
RS 485 / RS 422 interface converter | ||||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0599 | + | ||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0589 | + | ||||
RS 485 interface, 2-wire | ||||||
Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™ |
8012-1770 | + | ||||
Shelf, perforated | ||||||
|
8009-0511 | + | ||||
Temperature safety device class 2 | ||||||
with visual alarm (DIN 12880) |
8012-1794 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity value, including certificate |
DL20-0920 | + | |||
Leakage test |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL00-0034 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0500 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0830 | + | |||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | + | |||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0300 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0700 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0040 | + |
Designation |
MKT720-480V-C¹ |
MKT720-400V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9020-0365 | 9020-0387 |
Data | ||
Serie | MKT | MKT |
Performance Data Temperature | ||
Average cooling down time according to IEC 60068-3-5 [K/min] | 4 | 4 |
Average heating-up rate according to IEC 60068-3-5 [K/min] | 4.5 | 4.5 |
Cooling down time from 180 °C to -70 °C [min] | 120 | 120 |
Max. heat compensation at 25 °C [W] | 5000 | 5000 |
Temperature fluctuation depending on setpoint [± K] | 0.1…0.5 | 0.1…0.5 |
Temperature range | -70…180 | -70…180 |
Temperature variation depending on setpoint [± K] | 0.3…2 | 0.3…2 |
Electrical data | ||
Nominal power [kW] | 13 | 13 |
Phase (Nominal voltage) | 3~ | 3~ |
Power frequency [Hz] | 60 | 50 |
Rated Voltage [V] | 480 | 400 |
Unit fuse [A] | 32 | 32 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 1140 | 1140 |
Height net [mm] | 2005 | 2005 |
Width net [mm] | 1580 | 1580 |
Internal Dimensions | ||
Depth [mm] | 600 | 600 |
Height [mm] | 1020 | 1020 |
Width [mm] | 1200 | 1200 |
Measures | ||
Interior volume [L] | 734 | 734 |
Load per rack [kg] | 40 | 40 |
Net weight of the unit (empty) [kg] | 1 | 610 |
Permitted load [kg] | 160 | 160 |
Viewing window height [mm] | 300 | 300 |
Viewing window width [mm] | 508 | 508 |
Wall clearance back [mm] | 300 | 300 |
Wall clearance sidewise [mm] | 200 | 200 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 67 | 65 |
Fixtures | ||
Number of shelves (std./max.) | 1/11 | 1/11 |
Performance Data Temperature | ||
Average cooling down time according to IEC 60068-3-5 [K/min] | 4 | 4 |
Average heating-up rate according to IEC 60068-3-5 [K/min] | 4.5 | 4.5 |
Cooling down time from 180 °C to -70 °C [min] | 120 | 120 |
Max. heat compensation at 25 °C [W] | 5000 | 5000 |
Temperature fluctuation depending on setpoint [± K] | 0.1…0.5 | 0.1…0.5 |
Temperature range | -70…180 | -70…180 |
Temperature variation depending on setpoint [± K] | 0.3…2 | 0.3…2 |
Electrical data | ||
Nominal power [kW] | 13 | 13 |
Phase (Nominal voltage) | 3~ | 3~ |
Power frequency [Hz] | 60 | 50 |
Rated Voltage [V] | 480 | 400 |
Unit fuse [A] | 32 | 32 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 44.9 | 44.9 |
Height net [in] | 79 | 79 |
Width net [in] | 62.3 | 62.3 |
Internal Dimensions | ||
Depth [in] | 23.64 | 23.64 |
Height [in] | 40.2 | 40.2 |
Width [in] | 47.3 | 47.3 |
Measures | ||
Interior volume [cu.ft.] | 25.9 | 25.9 |
Load per rack [lbs] | 88 | 88 |
Net weight of the unit (empty) [lbs] | 2 | 1345 |
Permitted load [lbs] | 353 | 353 |
Viewing window height [in] | 11.82 | 11.82 |
Viewing window width [in] | 20.02 | 20.02 |
Wall clearance back [in] | 11.82 | 11.82 |
Wall clearance sidewise [in] | 7.88 | 7.88 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 67 | 65 |
Fixtures | ||
Number of shelves (std./max.) | 1/11 | 1/11 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
MKT 720 |
PDF (216.10 kB ) | > |
MKT 720 US version with imperial values |
PDF (211.36 kB) | > | |
Operating Manuals |
MK | MKT series |
PDF (9.73 MB) | > |
Technical Drawings |
Version MKT720-400V-C 9020-0365 |
PDF (415.46 kB) | > |
Technical Drawings |
Version MKT720-400V 9020-0387 |
PDF (410.47 kB) | > |
Case Studies |
Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors MinebeaMitsumi Technology Center Europe GmbH |
PDF (479.77 kB) | > |
White paper |
Trends in consumer behavior How has the food industry changed in industrialized countries? |
PDF (157.03 kB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Options & Accessories |
Data Logger Kits – temperature and humidity Data Logger Kit NET 100 | Data Logger Kit NET 100/60 |
PDF (256.74 kB) | > |
Brochures |
Battery test chambers with package A and package P for testing lithium-ion energy storage devices PACKAGE A | PACKAGE P |
PDF (256.93 kB) | > |
Brochures |
Dynamic climate chambers MK | MKF | MKT | MKFT series |
PDF (2.30 MB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |