Benefits
Important characteristics
Details of the model
Select version
MSRP* [?] | Merken | |
---|---|---|
Model FD 56 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | MSRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model FD 56 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
FD056-230V | 9010-0303 | - | + | ||
120 V 1~ 60 Hz | ||||||
Standard |
FD056UL-120V | 9010-0304 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-1019 | - | + | |||
left |
8012-1020 | - | + | |||
top |
8012-1671 | - | + | |||
top |
8012-1364 | - | + | |||
top |
8012-1380 | - | + | |||
right |
8012-1015 | - | + | |||
left |
8012-1016 | - | + | |||
left |
8012-1276 | - | + | |||
right |
8012-1269 | - | + | |||
top |
8012-1263 | - | + | |||
Alarm function for overheating | ||||||
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device |
8012-1636 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1624 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1116 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1135 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1573 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1594 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1552 | - | + | |||
Class 3.1 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1643 | - | + | |||
Clock | ||||||
battery-backed |
8012-1641 | - | + | |||
Data Logger Kit | ||||||
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0714 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-1648 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1665 | - | + | |||
Ethernet interface | ||||||
for Multi Management Software APT-COM™ |
8012-0988 | - | + | |||
Gas-tight option model | ||||||
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1683 | - | + | |||
Heating output, reinforced | ||||||
For faster heating up time and improved recovery time; max. 300 °C |
8012-1056 | - | + | |||
HEPA air filter | ||||||
On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) |
8012-1050 | - | + | |||
Inert gas connection | ||||||
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1689 | - | + | |||
Inner chamber, reinforced | ||||||
max. total load 85 kg |
8012-1053 | - | + | |||
Instrument tray | ||||||
with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm |
4022-0124 | - | + | |||
with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm |
4022-0123 | - | + | |||
Interior lighting | ||||||
with 15 W light bulb |
8012-1632 | - | + | |||
with 15 W light bulb |
8012-1628 | - | + | |||
Measurement of air exchange rate | ||||||
in accordance with ASTM D5374, definition and protocol according to ambient temperature |
8012-1195 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1620 | - | + | |||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | - | + | |||
Rack | ||||||
|
6004-0166 | - | + | |||
|
6004-0150 | - | + | |||
Rack, heavy load | ||||||
Stainless steel, max. load per rack 50 kg |
6004-0252 | - | + | |||
Stainless steel, max. load per rack 50 kg |
6004-0198 | - | + | |||
Rubber pads | ||||||
set anti-slip feet |
8012-1887 | - | + | |||
Shelf, perforated | ||||||
|
6004-0182 | - | + | |||
Table on castors | ||||||
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm |
9051-0018 | - | + | |||
Viewing window and interior lighting | ||||||
viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior |
8012-1700 | - | + | |||
viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior |
8012-1702 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL40-0100 | - | + | ||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | - | + | ||
Maintenance |
Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate |
DL20-0200 | - | + | ||
Measurement of air exchange rate |
including certificate (in accordance with ASTM D5374) |
DL33-0000 | - | + | ||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber including certificate |
DL30-0101 | - | + | ||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | - | + | ||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | - | + | ||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | - | + | ||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | - | + | ||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | - | + | ||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | - | + | ||
Warranty extension from 2 to 3 years |
The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded |
DL00-3041 | - | + | ||
Warranty extension from 2 to 5 years |
The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded |
DL00-3042 | - | + |
Designation |
FD056UL-120V¹ |
FD056-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0304 | 9010-0303 |
Data | ||
Serie | FD | FD |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 15 | 15 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Temperature range +10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.7 | 1.7 |
Air change data | ||
Air change (approx.) at 100 °C [x/h] | 80 | 80 |
Electrical data | ||
Nominal power [kW] | 1.2 | 1.1 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 60 | 50/60 |
Rated Voltage [V] | 120 | 230 |
Unit fuse [A] | 12.5 | 6.3 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 565 | 565 |
Height net [mm] | 625 | 625 |
Width net [mm] | 560 | 560 |
Internal Dimensions | ||
Depth [mm] | 345 | 345 |
Height [mm] | 440 | 440 |
Width [mm] | 400 | 400 |
Measures | ||
Interior volume [L] | 60 | 60 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 41 | 41 |
Permitted load [kg] | 70 | 70 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 290 | 290 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 15 | 15 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Temperature range +10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.7 | 1.7 |
Air change data | ||
Air change (approx.) at 100 °C [x/h] | 80 | 80 |
Electrical data | ||
Nominal power [kW] | 1.2 | 1.1 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 60 | 50/60 |
Rated Voltage [V] | 120 | 230 |
Unit fuse [A] | 12.5 | 6.3 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 22.26 | 22.26 |
Height net [in] | 24.63 | 24.63 |
Width net [in] | 22.06 | 22.06 |
Internal Dimensions | ||
Depth [in] | 13.59 | 13.59 |
Height [in] | 17.34 | 17.34 |
Width [in] | 15.76 | 15.76 |
Measures | ||
Interior volume [cu.ft.] | 2.1 | 2.1 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 90 | 90 |
Permitted load [lbs] | 154 | 154 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 290 | 290 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
FD 56 |
PDF (143.05 kB ) | > |
FD 56 US version with imperial values |
PDF (143.03 kB) | > | |
Operating Manuals |
Quick Start Guide BD | BF | ED | FD | FED series |
PDF (1.53 MB) | > |
Operating Manuals |
BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720 |
PDF (10.79 MB) | > |
Technical Drawings |
Version Interior dimensions |
PDF (233.88 kB) | > |
Technical Drawings |
Model FD 56 Interior dimensions |
PDF (181.87 kB) | > |
Technical Drawings |
Version Access ports |
PDF (93.29 kB) | > |
Technical Drawings |
Version Access ports BINDER INDIVIDUAL |
PDF (92.73 kB) | > |
Case Studies |
Drying and heating chambers (ED | FD series) - Testing the functionality and service life of cables U. I. Lapp GmbH |
PDF (189.08 kB) | > |
Case Studies |
Drying and heating chambers (FD series) - From toothbrushes to tool handles and seals in vehicles KRAIBURG TPE GmbH & Co. KG |
PDF (701.49 kB) | > |
Case Studies |
Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors MinebeaMitsumi Technology Center Europe GmbH |
PDF (479.77 kB) | > |
Case Studies |
Drying and heating chambers (FD series) - Cocoa beans hitting the spot Seguine Cacao Cocoa & Chocolate Advisors |
PDF (1.17 MB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Brochures |
Drying and heating chambers E | ED | ED-S | FD | FD-S | FED | FP | M series |
PDF (2.97 MB) | > |
Brochures |
BINDER Service 100 % performance and availability |
PDF (1.12 MB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |