Benefits
Important characteristics
Optional equipment
Details of the model
Select version
Merken | ||
---|---|---|
Model CBF 170 | ||
|
+ | |
|
+ | |
|
+ | |
|
+ |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model CBF 170 | ||||||
100…120 V 1~ 50/60 Hz | ||||||
with active humidification |
CBF170UL-120V | 9640-0019 | + | |||
with O₂ control 0.2–20% |
CBF170UL-120V-O | 9640-0020 | + | |||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
CBF170-230V | 9640-0017 | + | |||
with O₂ control 0.2–20% |
CBF170-230V-O | 9640-0018 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8612-0026 | + | ||||
right |
8612-0027 | + | ||||
back |
8612-0025 | + | ||||
Analog output 4-20 mA | ||||||
for temperature and CO₂ values (outputs not adjustable) |
8612-0022 | + | ||||
Base | ||||||
the base equipped with casters is used for the secure positioning and leveling of a BINDER CO₂ incubator |
9051-0028 | + | ||||
Calibration certificate O₂ | ||||||
for versions with O₂ control; a measuring point in center of chamber at a specified O₂ percentage value |
8012-0229 | + | ||||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1132 | + | ||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1571 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1550 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1592 | + | ||||
Calibration certificate, temperature and CO₂ | ||||||
for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂ |
8012-1235 | + | ||||
CELLROLL Set | ||||||
modular, expandable roller bottle system for cell cultivation, 4 roller bottles |
8612-0023 | + | ||||
Convenient water supply | ||||||
Set consisting of 10 liter water container with magnetic holder, hose adapter with practical quick coupling and water stop function, flexible positioning, enables water to be supplied to multiple CB units simultaneously via a water container, not pre-filled. |
8009-1128 | + | ||||
Copper interior fittings | ||||||
Set consisting of 3 shelves (all-copper) and a water pan (copper-plated), more information. |
8012-1918 | + | ||||
Door hinged on the left | ||||||
Unit door and standard glass inner door with door hinged on the left |
8612-0034 | + | ||||
Electric access port | ||||||
8-pin, for low voltage with LEMO socket (coverable) and LEMO plug (max. 24 V – 2 A) |
8612-0033 | + | ||||
Gas cylinder connection set | ||||||
for O₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0015 | + | ||||
for N₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0016 | + | ||||
for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0014 | + | ||||
Gas tank changer | ||||||
external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output |
8012-0408 | + | ||||
Inner door, divided | ||||||
Cell therapy compartmentalization, consisting of 6 inner doors and three shelf levels with one partition wall each |
8612-0030 | + | ||||
O₂ control range | ||||||
alternative to the standard range, for controlling O₂ concentrations between 10 and 95 vol. %, only in conjunction with option models with O₂ control |
8612-0028 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
Quick sample access | ||||||
vewing window (13 x 25 cm) in the inner door for quick access |
8612-0032 | + | ||||
Rubber pads | ||||||
set anti-slip feet |
8012-0702 | + | ||||
Shaker „Professional“ | ||||||
Shaker and controller equipped with LEMO connectors, exclusively for CB with electric access port, 100 – 240 V, 50/60 Hz |
8012-1772 | + | ||||
Shaker „Universal“ | ||||||
Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz |
8012-1771 | + | ||||
Shelf, perforated | ||||||
|
6004-0137 | + | ||||
for divided inner door |
8012-1888 | + | ||||
Stacking adapter | ||||||
for the thermally isolated stacking of two BINDER CO₂ incubators |
9051-0035 | + | ||||
Stacking frame | ||||||
stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units |
9051-0040 | + | ||||
Water supply | ||||||
Set consisting of 12 empty, refillable tubular bags including peristaltic tubing, connectors, and fine gas filters |
8009-1058 | + | ||||
Set consisting of 10 bottles, each with 1,000 ml of sterile humidification water, including peristaltic tubing, connectors, and fine gas filters |
8009-1104 | + | ||||
Set consisting of 3 empty, refillable tubular bags including peristaltic tubing, connectors, and fine gas filters |
8009-1083 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
CO₂ calibration |
CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate |
DL30-0401 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature and CO₂ value, including certificate |
DL20-0940 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
O₂ calibration |
O₂ calibration with 1 measuring point in center of chamber at a specified O₂ percentage value, including certificate |
DL30-0402 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | + | |||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0020 | + |
Designation |
CBF170UL-120V-O¹ |
CBF170UL-120V¹ |
CBF170-230V-O¹ |
CBF170-230V¹ |
---|---|---|---|---|
Option model | with O₂ control 0.2–20% | with active humidification | with O₂ control 0.2–20% | Standard |
Order number | 9640-0020 | 9640-0019 | 9640-0018 | 9640-0017 |
Data | ||||
Serie | CBF | CBF | CBF | CBF |
Performance Data Temperature | ||||
Recovery time after 30 seconds door open at 37 °C [min] | 6 | 6 | 6 | 6 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 60 °C | 60 °C | 60 °C | 60 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 | 0.4 | 0.4 |
Performance Data Climate | ||||
Humidity range | 90…95 | 90…95 | 90…95 | 90…95 |
Humidity range with active humidification [% RH] | 50…95 | 50…95 | 50…95 | 50…95 |
CO₂-Data | ||||
CO₂ measurement | IR | IR | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 | 5 | 5 |
O₂-Data | ||||
O₂ control ranges with option: O₂ range [Vol.-% O₂] | 10…95 | - | 10…95 | - |
O₂ Recovery time after 30 seconds door open at 5 Vol.-% O₂ [min] | 12 | - | 12 | - |
Standard O₂ control ranges: O₂ range [Vol.-% O₂] | 0.2…20 | - | 0.2…20 | - |
Electrical data | ||||
Nominal power [kW] | 1.4 | 1.4 | 1.4 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
Rated Voltage [V] | 100…120 | 100…120 | 200…230 | 200…230 |
Unit fuse [A] | 16 | 16 | 10 | 10 |
Doors | ||||
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||||
Depth net [mm] | 715 | 715 | 715 | 715 |
Height net [mm] | 870 | 870 | 870 | 870 |
Width net [mm] | 680 | 680 | 680 | 680 |
Internal Dimensions | ||||
Depth [mm] | 505 | 505 | 505 | 505 |
Height [mm] | 600 | 600 | 600 | 600 |
Width [mm] | 560 | 560 | 560 | 560 |
Measures | ||||
Interior volume [L] | 170 | 170 | 170 | 170 |
Load per rack [kg] | 10 | 10 | 10 | 10 |
Net weight of the unit (empty) [kg] | 95 | 95 | 95 | 95 |
Permitted load [kg] | 30 | 30 | 30 | 30 |
Wall clearance back [mm] | 100 | 100 | 100 | 100 |
Wall clearance sidewise [mm] | 50 | 50 | 50 | 50 |
Environment-specific data | ||||
Energy consumption at 37 °C [Wh/h] | 55 | 55 | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 | 41 | 41 |
Fixtures | ||||
Number of shelves (std./max.) | 3/6 | 3/6 | 3/6 | 3/6 |
Performance Data Temperature | ||||
Recovery time after 30 seconds door open at 37 °C [min] | 6 | 6 | 6 | 6 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 60 °C | 60 °C | 60 °C | 60 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 | 0.4 | 0.4 |
Performance Data Climate | ||||
Humidity range | 90…95 | 90…95 | 90…95 | 90…95 |
Humidity range with active humidification [% RH] | 50…95 | 50…95 | 50…95 | 50…95 |
CO₂-Data | ||||
CO₂ measurement | IR | IR | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 | 5 | 5 |
O₂-Data | ||||
O₂ control ranges with option: O₂ range [Vol.-% O₂] | 10…95 | - | 10…95 | - |
O₂ Recovery time after 30 seconds door open at 5 Vol.-% O₂ [min] | 12 | - | 12 | - |
Standard O₂ control ranges: O₂ range [Vol.-% O₂] | 0.2…20 | - | 0.2…20 | - |
Electrical data | ||||
Nominal power [kW] | 1.4 | 1.4 | 1.4 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
Rated Voltage [V] | 100…120 | 100…120 | 200…230 | 200…230 |
Unit fuse [A] | 16 | 16 | 10 | 10 |
Doors | ||||
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||||
Depth net [in] | 28.17 | 28.17 | 28.17 | 28.17 |
Height net [in] | 34.28 | 34.28 | 34.28 | 34.28 |
Width net [in] | 26.79 | 26.79 | 26.79 | 26.79 |
Internal Dimensions | ||||
Depth [in] | 19.9 | 19.9 | 19.9 | 19.9 |
Height [in] | 23.64 | 23.64 | 23.64 | 23.64 |
Width [in] | 22.06 | 22.06 | 22.06 | 22.06 |
Measures | ||||
Interior volume [cu.ft.] | 6 | 6 | 6 | 6 |
Load per rack [lbs] | 22 | 22 | 22 | 22 |
Net weight of the unit (empty) [lbs] | 209 | 209 | 209 | 209 |
Permitted load [lbs] | 66 | 66 | 66 | 66 |
Wall clearance back [in] | 3.94 | 3.94 | 3.94 | 3.94 |
Wall clearance sidewise [in] | 1.97 | 1.97 | 1.97 | 1.97 |
Environment-specific data | ||||
Energy consumption at 37 °C [Wh/h] | 55 | 55 | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 | 41 | 41 |
Fixtures | ||||
Number of shelves (std./max.) | 3/6 | 3/6 | 3/6 | 3/6 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
CBF 170 |
PDF (145.53 kB ) | > |
CBF 170 US version with imperial values |
PDF (145.05 kB) | > | |
Technical Drawings |
Version CB 170 External dimensions |
PDF (365.83 kB) | > |
Technical Drawings |
Version CB 170 Access ports |
PDF (180.29 kB) | > |
Technical Drawings |
Version CBF170-230V 9040-0133 |
PDF (437.45 kB) | > |
Case Studies |
CO₂ incubator (CB series) - Herd breeding BETAGRAN Lipetsk LLC, Lipetsk |
PDF (306.70 kB) | > |
Case Studies |
CO₂ incubator (CB series) - Stem cell research into healing musculoskeletal disorders University of Rochester School of Medicine and Dentistry |
PDF (224.21 kB) | > |
Case Studies |
CO₂ incubators (CB series) - BINDER chambers are used in cancer research Klinikum rechts der Isar (Rechts der Isar Hospital) Technical University of Munich |
PDF (264.13 kB) | > |
Case Studies |
CO₂ incubators (CB series) - Lucerne University of Applied Sciences and Arts delivers new findings in the field of space biology Lucerne University of Applied Sciences and Arts |
PDF (205.99 kB) | > |
Case Studies |
CO₂ incubators (CB series) - Stem cell research The Huck Institutes of the Life Sciences Pennsylvania State University |
PDF (1.23 MB) | > |
Case Studies |
CO₂ incubators (CB series) – Successful reproduction of human skin cells Sysmex Suisse AG |
PDF (199.78 kB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.52 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Cell cultivation: for and against particular technical solutions in co2 incubators The parameters to consider |
PDF (184.18 kB) | > |
White paper |
Cell cultivation without contamination Hot air sterilization and other means of contamination control in CO₂ incubators |
PDF (245.02 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Options & Accessories |
Stacking options for BINDER CO₂ incubators C | CB series |
PDF (158.75 kB) | > |
Options & Accessories |
BINDER CO₂-shaker CB 170 | CB 260 | CB-S 170 | CB-S 260 series |
PDF (188.87 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |
Buyer´s Guide |
CO₂ incubators 6 things to consider when buying CO₂ incubators |
PDF (425.35 kB) | > |