Series BF | Incubators Avantgarde.Line with forced convection

Important characteristics

  • Temperature range (model 56 | 260): ambient temperature plus 7 °C to 100 °C
  • Temperature range (model 115): ambient temperature plus 8 °C to 100 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data
Models
  • Model BF 56
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 560 x 625 x 565
  • Internal dimension W x H x D [in]: 400 x 440 x 340
  • Net weight [lbs]: 39
  • Interior volume [cu.ft.]: 59
  • Bookmark +
  • Model BF 115
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 710 x 735 x 605
  • Internal dimension W x H x D [in]: 550 x 550 x 380
  • Net weight [lbs]: 54
  • Interior volume [cu.ft.]: 114
  • Bookmark +
  • Model BF 260
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 810 x 965 x 760
  • Internal dimension W x H x D [in]: 650 x 780 x 510
  • Net weight [lbs]: 85
  • Interior volume [cu.ft.]: 257
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
MSRP* [?] Merken
  • Designation:

    Calibration temperature incl. certificate

  • Description:

    including certificate, one measuring point in center of chamber at specified temperature

  • Art. No.: DL30-0101
- +
  • Designation:

    Data Logger Kit installation service

  • Description:

    unit function instructions for operation and programming of the controller

  • Art. No.: DL10-0400
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    in accordance with qualification folder

  • Art. No.: DL40-0100
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    in accordance with customer's requirement, price: on request

  • Art. No.: DL44-0500
- +
  • Designation:

    Extension of the warranty from 2 to 3 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL01-7041
- +
  • Designation:

    Extension of the warranty from 2 to 5 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL01-7042
- +
  • Designation:

    Installation

  • Description:

    and set up of unit at operating location, connect to existing connections

  • Art. No.: DL10-0100
- +
  • Designation:

    Preventive maintenance

  • Description:

    Executive of equipment inspection according to maintenance plan

  • Art. No.: DL20-0200
- +
  • Designation:

    Qualification folder IQ/OQ

  • Description:

    supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001

  • Art. No.: 8012-0871
- +
  • Designation:

    Qualification folder IQ/OQ/PQ

  • Description:

    supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ

  • Art. No.: 8012-0959
- +
  • Designation:

    Temperature measurement 18 measuring points

  • Description:

    including certificate, 18 measuring points at specified temperature

  • Art. No.: DL30-0118
- +
  • Designation:

    Temperature measurement 27 measuring points

  • Description:

    including certificate, 27 measuring points at specified temperature

  • Art. No.: DL30-0127
- +
  • Designation:

    Temperature measurement 9 measuring points

  • Description:

    including certificate, 9 measuring points at specified temperature

  • Art. No.: DL30-0109
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260

  • Category: Operating Manuals
  • File type / size PDF (10.24 MB)

Quick Start Guide BD | BF | ED | FD | FED series

  • Category: Operating Manuals
  • File type / size PDF (2.54 MB)

BD | BF Incubators & KB | KT Refrigerated Incubators Fact Sheet

  • Category: Brochures
  • File type / size PDF (2.31 MB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (499.17 kB)
You will find further model sizes in the Classic.Line >

Incubators with forced convection for challenging incubation tasks

BINDER offers incubators to suit different laboratory requirements. Alongside incubators with mechanical adjustment, the Classic.Line also includes incubators with natural convection and, in the BF series, incubators with forced convection, which guarantee quick temperature equalization through forced convection after the chamber door has been opened.
Operating within a temperature range of between 5 °C and 100 °C, these incubators with forced convection all have an adjustable exhaust air flap and the fan speed can be adjusted on an individual basis. The proven APT.line™ preheating chamber technology and the cooling system guarantee maximum precision and results that are reproducible in every laboratory test.

Incubators with forced convection for precision, functionality, and usability

The BINDER BF series incubators with forced convection are also ideal for challenging incubation tasks, with safety and precision guaranteed even when fully loaded and under high batch throughputs. Operation with forced convection is unbelievably homogeneous, while the incubator also offers speedy recovery times. The incubator with forced convection boasts high usability thanks to its straightforward controller with timer functions. The units can be stacked on top of one another for an optimum ratio between use and space needed. Reliable decontamination is another advantage afforded by these incubators. The disinfection routine at 100 °C minimizes the risk of contamination, while the premium stainless steel inner chamber does not have any built-in fixtures, allowing for ease of cleaning.
This BINDER incubator with forced convection is energy efficient, so is also extremely economical during operation.