Series M | Drying and heating chambers Classic.Line with forced convection and advanced program functions

Important characteristics

  • Temperature range: room temperature plus 5 °C to 300 °C
  • APT.line™ preheating chamber technology
  • Adjustable fan speed
  • Program-controlled ventilation flap
  • Color LCD controller with time-segment programming
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Computer interface: RS 422
Models
  • Model M 53
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 635 x 780 x 575
  • Internal dimension W x H x D [mm]: 400 x 400 x 340
  • Net weight [kg]: 61
  • Interior volume [L]: 53
  • Bookmark +
  • Model M 115
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 835 x 865 x 645
  • Internal dimension W x H x D [mm]: 600 x 480 x 410
  • Net weight [kg]: 89
  • Interior volume [L]: 115
  • Bookmark +
  • Model M 240
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 1035 x 985 x 745
  • Internal dimension W x H x D [mm]: 800 x 600 x 510
  • Net weight [kg]: 131
  • Interior volume [L]: 240
  • Bookmark +
  • Model M 400
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 1235 x 1190 x 795
  • Internal dimension W x H x D [mm]: 1000 x 800 x 510
  • Net weight [kg]: 173
  • Interior volume [L]: 400
  • Bookmark +
  • Model M 720
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 1235 x 1690 x 865
  • Internal dimension W x H x D [mm]: 1000 x 1200 x 610
  • Net weight [kg]: 203
  • Interior volume [L]: 720
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
MSRP* [?] Merken
  • Designation:

    Calibration temperature incl. certificate

  • Description:

    including certificate, one measuring point in center of chamber at specified temperature

  • Art. No.: DL300101
- +
  • Designation:

    Data Logger Kit installation service

  • Description:

    unit function instructions for operation and programming of the controller

  • Art. No.: DL100600
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    in accordance with qualification folder

  • Art. No.: DL410200
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    in accordance with customer's requirement, price: on request

  • Art. No.: DL440500
- +
  • Designation:

    Extension of the warranty from 2 to 3 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL010041
- +
  • Designation:

    Extension of the warranty from 2 to 5 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL010042
- +
  • Designation:

    Installation

  • Description:

    and set up of unit at operating location, connect to existing connections

  • Art. No.: DL100100
- +
  • Designation:

    Measurement of air exchange rate

  • Description:

    including certificate (in accordance with ASTM D5374)

  • Art. No.: DL330000
- +
  • Designation:

    Preventive maintenance

  • Description:

    Executive of equipment inspection according to maintenance plan

  • Art. No.: DL200200
- +
  • Designation:

    Qualification folder IQ/OQ

  • Description:

    supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001

  • Art. No.: 8012-0862
- +
  • Designation:

    Qualification folder IQ/OQ/PQ

  • Description:

    supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ

  • Art. No.: 8012-0950
- +
  • Designation:

    Temperature measurement 18 measuring points

  • Description:

    including certificate, 18 measuring points at specified temperature

  • Art. No.: DL300118
- +
  • Designation:

    Temperature measurement 27 measuring points

  • Description:

    including certificate, 27 measuring points at specified temperature

  • Art. No.: DL300127
- +
  • Designation:

    Temperature measurement 9 measuring points

  • Description:

    including certificate, 9 measuring points at specified temperature

  • Art. No.: DL300109
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

M series

  • Category: Operating Manuals
  • File type / size PDF (6.09 MB)

ED | FD | FED | FP Ovens Fact Sheets

  • Category: Brochures
  • File type / size PDF (1.11 MB)

Artificial aging Predicting material behavior

  • Category: White paper
  • File type / size PDF (435.64 kB)

Heating chambers with forced convection and advanced program functions
BINDER heating chambers in the Classic.Line M series are equipped with advanced program functions, allowing the units to be used in a wide range of applications. Whatever they are being used for, they never fall to impress with their high precision and performance. The drying and heating chambers with forced convection are ideally suited for the drying and heat treatment of solid or powdered chamber loads and bulk material with the introduction of heat. They also come highly recommended for drying processes and any tasks within the field of material and aging testing.

Heating chambers with forced convection for high performance and ease of use
Heating chambers in the M series feature an extremely powerful throughput of air and a programmable exhaust air flap that speeds up the heating up time. Testing temperatures can be maintained with precision at every level and are subject to only minimal spatial fluctuations. It is the patented APT.line™ preheating chamber technology together with the direct and streamlined air flow in the interior that guarantee the high levels of temperature accuracy in terms of space and time. These heating chambers operate within a temperature range of between 5 °C and 300 °C, with the temperature being displayed digitally to the accuracy of a tenth of a degree, and the fan speed can be adjusted on an individual basis.
BINDER heating chambers in the M series come in different sizes, and a range of optional accessories is also available. Their high performance levels are teamed with incredible ease of handling – all of the unit's functions are clearly arranged and user-friendly. The simplicity with which all of the parts in the heating chambers can be cleaned is another definite plus that reduces the risk of undesirable contamination to a minimum.