Model FP 400

Important characteristics
    • Temperature range: room temperature plus 5 °C to 300 °C
    • APT.line™ preheating chamber technology
    • Adjustable fan speed
    • Adjustable exhaust air flap
    • Controller with time-segment and real-time programming
    • 2 chrome-plated racks
    • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
    • Computer interface: RS 422
Model 400
Request Model FP 400 >
Option model:
Voltage:
Details of the model
Technical data
Downloads
  • Select version
    Rated voltage Option model Version Art. No. RRP* [?] Selection Bookmark
    Model FP 400
    400 V 3~ 50/60 Hz

    Standard

    FP400-400V¹ 9010-0265 - +
    208 V 3~ 60 Hz

    Standard

    FP400UL-208V¹ 9010-0266 - +
    * Recommended retail price (Installation not included): local prices might vary based on the following factors
    - Freight and transport insurance as all prices are ExWorks Germany
    - Customs fees and local taxes
    - Currency exchange rates
  • Options & accessories for FP 400 (77 results)
     
    Designation Description Art. No. RRP* [?] Bookmark
    Access port with silicone plug

    right

    100 mm
    8012-1507 - +

    top

    100 mm
    8012-1389 - +
    50 mm
    8012-1386 - +

    top

    50 mm
    8012-1382 - +

    left

    50 mm
    8012-1378 - +

    right

    50 mm
    8012-1374 - +
    30 mm
    8012-1370 - +

    top

    30 mm
    8012-1366 - +

    left

    30 mm
    8012-1362 - +

    right

    30 mm
    8012-1357 - +
    10 mm
    8012-1286 - +

    left

    10 mm
    8012-1279 - +

    right

    10 mm
    8012-1272 - +

    top

    10 mm
    8012-1265 - +

    10 mm, top

    8012-0386 - +

    10 mm, right

    8012-0387 - +

    10 mm, left

    8012-0388 - +

    10 mm, back

    8012-0390 - +

    30 mm, right

    8012-0536 - +

    30 mm, left

    8012-0537 - +

    30 mm, top

    8012-0539 - +

    30 mm, back

    8012-0540 - +

    50 mm, right

    8012-0541 - +

    50 mm, left

    8012-0542 - +

    50 mm, top

    8012-0545 - +

    50 mm, back

    8012-0546 - +

    100 mm, top

    8012-0547 - +

    100 mm, right

    8012-0721 - +

    100 mm, left

    8012-0722 - +
    Analog output, 4 – 20 mA

    for temperature values (output not adjustable)

    8012-0481 - +
    Calibration certificate, expanded

    for temperature; for extending the measurement in center of chamber to include another test temperature

    8012-1119 - +
    Calibration certificate, temperature

    temperature measurement incl. certificate and 27 measuring points at specified temperature

    8012-1597 - +

    temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

    8012-1576 - +

    temperature measurement incl. certificate, 9 measuring points at specified temperature

    8012-1555 - +

    for temperature, measurement in center of chamber at specified temperature

    8012-1138 - +

    temperature measurement incl. certificate, 9 measuring points at specified temperature

    8012-0915 - +

    temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

    8012-0918 - +

    temperature measurement incl. certificate and 27 measuring points at specified temperature

    8012-0921 - +
    Cart

    Cart – stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

    9051-0019 - +
    Class 3.1 independent temperature safety device

    with visual alarm (DIN 12880)

    8012-1149 - +
    Door gasket

    made of FKM, silicone-free

    8012-1311 - +

    made of FKM, silicone-free

    8012-0497 - +
    Door lock

    lockable door handle

    8012-1255 - +

    lockable door handle

    8012-0319 - +
    Fan, reinforced

    to increase air change rates

    208 V option model
    8012-1236 - +

    to increase air change rates

    400 V option model
    8012-1200 - +
    Inner chamber, reinforced

    including 2 reinforced racks (max. total load 250 kg, max. load per rack 70 kg)

    8012-1257 - +

    including 2 reinforced racks (max. total load 250 kg, max. load per rack 70 kg)

    8012-0339 - +
    Instrument tray

    with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm

    small
    4022-0123 - +

    with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm

    large
    4022-0124 - +
    Interface converter

    RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit

    230 V, 50/60 Hz option model
    8012-0380 - +

    RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit

    120 V, 60 Hz option model
    8012-0405 - +

    RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit

    230 V, 50/60 Hz option model
    8012-0556 - +

    RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit

    120 V, 60 Hz option model
    8012-0557 - +
    Interface converter, USB / RS422

    RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter)

    8012-0665 - +
    Measurement of air exchange rate

    in accordance with ASTM D5374, definition and protocol according to ambient temperature

    8012-1198 - +

    in accordance with ASTM D5374, definition and protocol according to ambient temperature

    8012-0195 - +
    pH-neutral detergent

    concentrated, for gentle remove of residual contaminants; 1 kg

    1002-0016 - +
    Pt 100 temperature sensor

    additional flexible Pt 100, interior, for displaying the temperature on the unit display

    8012-0504 - +
    Rack

    stainless steel

    6004-0011 - +

    chrome plated

    6004-0005 - +
    Rack accessories

    Rack accessories – fasteners (1 set of 4) for additional security of racks

    8012-0531 - +
    Rack, reinforced

    stainless steel, with 1 set of 4 fasteners, max. load 70 kg

    8012-0346 - +
    RS 422 interface

    modular plug distributor for 10 RS 422 interfaces

    8012-0295 - +
    RS 422 interface, cable (15 m)

    RS 422 connection cable (15 m) between plug distributor and RS 422 interface

    5023-0036 - +
    RS 422 interface, cable (50 m)

    RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor

    5023-0117 - +
    Shelf, perforated

    stainless steel

    6004-0029 - +

    stainless steel

    6004-0032 - +
    Software

    APT-COM™ communications software, price: for free

    version 3, GLP DEMO Edition
    9053-0008 - +

    APT-COM™ communications software

    version 3, STANDARD edition
    9053-0013 - +

    APT-COM™ communications software

    version 3, BASIC edition
    9053-0014 - +

    APT-COM™ communications software

    version 3, GLP edition
    9053-0015 - +

    APT-COM™ communications software

    version 2 to 3, GLP edition
    9053-0016 - +
    Viewing window and interior lighting

    viewing window in each door, 470 x 290 mm, and 30 W interior lighting

    230 V option model
    8012-0060 - +

    viewing window in each door, 470 x 290 mm, and 30 W interior lighting

    120 V option model
    8012-0240 - +
    Zero voltage relay contacts

    for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A)

    230 V option model
    8012-0471 - +

    for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A)

    120 V option model
    8012-0472 - +
    * Recommended retail price (Installation not included): local prices might vary based on the following factors
    - Freight and transport insurance as all prices are ExWorks Germany
    - Customs fees and local taxes
    - Currency exchange rates
  • Services for FP 400 (14 results)
     
    Designation Description Art. No. RRP* [?] Bookmark

    Data Logger Kit calibration service

    including certificate, one measuring point in center of chamber at specified temperature

    DL300101 - +

    Data Logger Kit installation service

    unit function instructions for operation and programming of the controller

    DL100500 - +

    Data Logger Kit validation service

    in accordance with qualification folder

    DL410200 - +

    Execution of IQ/OQ/PQ

    in accordance with customer's requirement, price: on request

    DL440500 - +

    Extension of the warranty from 2 to 3 years

    beginning with the date of delivery, wearing parts are not included

    DL005041 - +

    Extension of the warranty from 2 to 5 years

    beginning with the date of delivery, wearing parts are not included

    DL005042 - +

    Installation

    and set up of unit at operating location, connect to existing connections

    DL100100 - +

    Measurement of air exchange rate

    including certificate (in accordance with ASTM D5374)

    DL330000 - +

    Preventive maintenance

    Executive of equipment inspection according to maintenance plan

    DL200200 - +

    Qualification folder IQ/OQ

    supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001

    8012-0856 - +

    Qualification folder IQ/OQ/PQ

    supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ

    8012-0945 - +

    Temperature measurement 18 measuring points

    including certificate, 18 measuring points at specified temperature

    DL300118 - +

    Temperature measurement 27 measuring points

    including certificate, 27 measuring points at specified temperature

    DL300127 - +

    Temperature measurement 9 measuring points

    including certificate, 9 measuring points at specified temperature

    DL300109 - +
    * Recommended retail price (Installation not included): local prices might vary based on the following factors
    - Freight and transport insurance as all prices are ExWorks Germany
    - Customs fees and local taxes
    - Currency exchange rates
Designation FP400-400V¹ FP400UL-208V¹
Option model Standard Standard
Order number 9010-0265 9010-0266
Performance Data Temperature
Temperature range 5 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 2.5 2.5
Temperature fluctuation at 150 °C [± K] 0.3 0.3
Heating-up time to 150 °C [min] 35 35
Recovery time after 30 seconds door open at 150 °C [min] 17 17
Air change data
Air change (approx.) at 150 °C [x/h] 18 18
Electrical data
Rated Voltage [V] 400 208
Power frequency [Hz] 50/60 60
Nominal power [kW] 3.4 3.4
Unit fuse [A] 3 x 16 3 x 16
Phase (Nominal voltage) 3~ 3~
Measures
Interior volume [L] 400 400
Net weight of the unit (empty) [kg] 145 145
permitted load [kg] 90 90
Load per rack [kg] 35 35
Measures - Internal Dimensions
Width [mm] 1000 1000
Height [mm] 800 800
Depth [mm] 510 510
Measures - Outer dimensions
Width net [mm] 1235 1235
Height net [mm] 1025 1025
Depth net [mm] 765 765
Wall clearance back [mm] 160 160
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 150 °C 1200 Wh/h 1200 Wh/h
Fixtures
Number of shelves (std./max.) 2/10 2/10
Performance Data Temperature
Temperature range 5 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 2.5 2.5
Temperature fluctuation at 150 °C [± K] 0.3 0.3
Heating-up time to 150 °C [min] 35 35
Recovery time after 30 seconds door open at 150 °C [min] 17 17
Air change data
Air change (approx.) at 150 °C [x/h] 18 18
Electrical data
Rated Voltage [V] 400 208
Power frequency [Hz] 50/60 60
Nominal power [kW] 3.4 3.4
Unit fuse [A] 3 x 16 3 x 16
Phase (Nominal voltage) 3~ 3~
Measures
Interior volume [cu.ft.] 14.1 14.1
Net weight of the unit (empty) [lbs] 320 320
permitted load [lbs] 198 198
Load per rack [lbs] 77 77
Measures - Internal Dimensions
Width [in] 39.4 39.4
Height [in] 31.52 31.52
Depth [in] 20.09 20.09
Measures - Outer dimensions
Width net [in] 48.7 48.7
Height net [in] 40.4 40.4
Depth net [in] 30.14 30.14
Wall clearance back [in] 6.3 6.3
Wall clearance sidewise [in] 3.94 3.94
Environment-specific data
Energy consumption at 150 °C 1200 Wh/h 1200 Wh/h
Fixtures
Number of shelves (std./max.) 2/10 2/10
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Category Title File type / size Download
Data Sheets
FP 400

PDF (175.02 kB)
FP 400
US version with imperial values
PDF (162.70 kB)
Operating Manuals FP series
PDF (6.87 MB)
Technical Drawings Model FP 400
External dimensions
PDF (76.34 kB)
Technical Drawings Model FP 400
Access ports
PDF (76.34 kB)
Case Studies Drying and heating chambers (Series FP) - Material / quality testing
UL International Thermoplastic Testing Center
PDF (305.24 kB)
Case Studies Drying and heating chambers (Series FP) - Curing of encapsulant material
Odelo LED GmbH
PDF (1.24 MB)
Product Catalog BINDER Industrial
Product catalog 2014 | 2015
PDF (11.92 MB)
Product Catalog BINDER Scientific
Product catalog
PDF (10.32 MB)
Brochures BINDER image brochure
Perfection in every detail
PDF (3.91 MB)
White paper Artificial aging
Predicting material behavior
PDF (435.64 kB)