Important characteristics
Details of the model
Select version
MSRP* [?] | Merken | |
---|---|---|
Model FD 23 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | MSRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model FD 23 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
FD023-230V¹ | 9010-0194 | - | + | ||
120 V 1~ 60 Hz | ||||||
Standard |
FD023UL-120V¹ | 9010-0196 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
back |
8012-1283 | - | + | |||
right |
8012-1354 | - | + | |||
left |
8012-1359 | - | + | |||
back |
8012-1368 | - | + | |||
right |
8012-1372 | - | + | |||
left |
8012-1376 | - | + | |||
back |
8012-1384 | - | + | |||
top |
8012-1263 | - | + | |||
right |
8012-1269 | - | + | |||
left |
8012-1276 | - | + | |||
top |
8012-1364 | - | + | |||
top |
8012-1380 | - | + | |||
Alarm function for overheating | ||||||
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device |
8012-1300 | - | + | |||
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device |
8012-1304 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-0431 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1116 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1135 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1552 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1573 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1594 | - | + | |||
Class 3.1 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1147 | - | + | |||
Data Logger Kit | ||||||
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0714 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-1306 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1247 | - | + | |||
Instrument tray | ||||||
with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm |
4022-0123 | - | + | |||
with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm |
4022-0124 | - | + | |||
Measurement of air exchange rate | ||||||
in accordance with ASTM D5374, definition and protocol according to ambient temperature |
8012-1195 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin) |
8012-1174 | - | + | |||
Rack accessories | ||||||
Rack accessories – fasteners (1 set of 4) for additional security of racks |
8012-0531 | - | + | |||
Racks | ||||||
chrome-plated |
6004-0050 | - | + | |||
stainless steel |
6004-0051 | - | + | |||
Shelf, perforated | ||||||
|
6004-0052 | - | + | |||
Viewing window and interior lighting | ||||||
viewing window in door, 180 x 180 mm, and 15 W interior lighting |
8012-1259 | - | + | |||
viewing window in door, 180 x 180 mm, and 15 W interior lighting |
8012-1260 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL40-0100 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL00-3041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL00-3042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0100 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0400 | - | + | ||
Measurement of air exchange rate |
including certificate (in accordance with ASTM D5374) |
DL33-0000 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0200 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0792 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0943 | - | + | ||
Temperature measurement 18 measuring points |
including certificate, 18 measuring points at specified temperature |
DL30-0118 | - | + | ||
Temperature measurement 27 measuring points |
including certificate, 27 measuring points at specified temperature |
DL30-0127 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation | FD023UL-120V¹ | FD023-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0196 | 9010-0194 |
Measures | ||
Interior volume [L] | 20 | 20 |
Net weight of the unit (empty) [kg] | 27 | 27 |
permitted load [kg] | 25 | 25 |
Load per rack [kg] | 12 | 12 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Width [mm] | 222 | 222 |
Height [mm] | 330 | 330 |
Depth [mm] | 300 | 300 |
Outer dimensions | ||
Width net [mm] | 435 | 435 |
Height net [mm] | 495 | 495 |
Depth net [mm] | 520 | 520 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 300 | 300 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Temperature range 5 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 2.5 | 2.5 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Heating-up time to 150 °C [min] | 25 | 25 |
Recovery time after 30 seconds door open at 150 °C [min] | 6 | 6 |
Air change data | ||
Air change (approx.) at 150 °C [x/h] | 64 | 64 |
Electrical data | ||
Rated Voltage [V] | 120 | 230 |
Power frequency [Hz] | 60 | 50/60 |
Nominal power [kW] | 0.8 | 0.8 |
Unit fuse [A] | 12.5 | 10 |
Phase (Nominal voltage) | 1~ | 1~ |
Measures | ||
Interior volume [cu.ft.] | 0.7 | 0.7 |
Net weight of the unit (empty) [lbs] | 60 | 60 |
permitted load [lbs] | 55 | 55 |
Load per rack [lbs] | 26 | 26 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Width [in] | 8.75 | 8.75 |
Height [in] | 13 | 13 |
Depth [in] | 11.82 | 11.82 |
Outer dimensions | ||
Width net [in] | 17.14 | 17.14 |
Height net [in] | 19.5 | 19.5 |
Depth net [in] | 20.49 | 20.49 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 300 | 300 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Temperature range 5 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 2.5 | 2.5 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Heating-up time to 150 °C [min] | 25 | 25 |
Recovery time after 30 seconds door open at 150 °C [min] | 6 | 6 |
Air change data | ||
Air change (approx.) at 150 °C [x/h] | 64 | 64 |
Electrical data | ||
Rated Voltage [V] | 120 | 230 |
Power frequency [Hz] | 60 | 50/60 |
Nominal power [kW] | 0.8 | 0.8 |
Unit fuse [A] | 12.5 | 10 |
Phase (Nominal voltage) | 1~ | 1~ |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
FD 23 |
PDF (164.96 kB ) | > |
FD 23 US version with imperial values |
PDF (165.10 kB) | > | |
Operating Manuals |
BD | ED | FD series Classic.Line Models |
PDF (6.88 MB) | > |
Case Studies |
Drying and heating chambers (Series FD) - From toothbrushes to tool handles and seals in vehicles KRAIBURG TPE GmbH & Co. KG |
PDF (701.49 kB) | > |
Case Studies |
Drying and heating chambers (Series ED | FD) - Textile research Textilforschungsinstitut Thüringen-Vogtland e.V. |
PDF (833.10 kB) | > |
Case Studies |
Drying and heating chambers (Series FD) - Cocoa beans hitting the spot Seguine Cacao Cocoa & Chocolate Advisors |
PDF (1.17 MB) | > |
Brochures |
Drying and heating chambers E | ED | FD | FED | FP | M series |
PDF (2.40 MB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |