Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model FD 260 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model FD 260 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
FD260-230V | 9010-0309 | - | + | ||
240 V 1~ 60 Hz | ||||||
Standard |
FD260UL-240V | 9010-0310 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
top |
8012-1671 | - | + | |||
top |
8012-1380 | - | + | |||
top |
8012-1364 | - | + | |||
left |
8012-1276 | - | + | |||
right |
8012-1269 | - | + | |||
top |
8012-1263 | - | + | |||
left |
8012-1020 | - | + | |||
right |
8012-1019 | - | + | |||
left |
8012-1016 | - | + | |||
right |
8012-1015 | - | + | |||
right |
8012-1028 | - | + | |||
left |
8012-1027 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1624 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1116 | - | + | |||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1594 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1573 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1552 | - | + | |||
for temperature, measurement in center of chamber at specified temperature |
8012-1135 | - | + | |||
Class 3.1 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1643 | - | + | |||
Clock | ||||||
battery-backed |
8012-1641 | - | + | |||
Data Logger Kit | ||||||
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0714 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-1652 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1665 | - | + | |||
Ethernet interface | ||||||
for Multi Management Software APT-COM™ |
8012-0988 | - | + | |||
Gas-tight option model | ||||||
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1687 | - | + | |||
HEPA air filter | ||||||
On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) |
8012-1052 | - | + | |||
Inert gas connection | ||||||
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1693 | - | + | |||
Inner chamber, reinforced | ||||||
max. total load 300 kg |
8012-1055 | - | + | |||
Instrument tray | ||||||
with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm |
4022-0124 | - | + | |||
with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm |
4022-0123 | - | + | |||
Interior lighting | ||||||
with 15 W light bulb |
8012-1628 | - | + | |||
Load management | ||||||
to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012) |
8012-1646 | - | + | |||
Measurement of air exchange rate | ||||||
in accordance with ASTM D5374, definition and protocol according to ambient temperature |
8012-1195 | - | + | |||
Overheating alarm | ||||||
audible, can be switched off, adjustable limit on the independent temperature safety device |
8012-1636 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1620 | - | + | |||
Rack | ||||||
chrome plated |
6004-0169 | - | + | |||
stainless steel |
6004-0153 | - | + | |||
Rack, heavy load | ||||||
Stainless steel, max. load per rack 70 kg |
6004-0200 | - | + | |||
Rubber pads | ||||||
set anti-slip feet |
8012-1887 | - | + | |||
Shelf, perforated | ||||||
|
6004-0185 | - | + | |||
Table on castors | ||||||
stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm |
9051-0019 | - | + | |||
Viewing window and interior lighting | ||||||
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior |
8012-1710 | - | + | |||
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior |
8012-1708 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL40-0100 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL00-3041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL00-3042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0100 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0500 | - | + | ||
Measurement of air exchange rate |
including certificate (in accordance with ASTM D5374) |
DL33-0000 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0200 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0792 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0943 | - | + | ||
Temperature measurement 18 measuring points |
including certificate, 18 measuring points at specified temperature |
DL30-0118 | - | + | ||
Temperature measurement 27 measuring points |
including certificate, 27 measuring points at specified temperature |
DL30-0127 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation |
FD260-230V¹ |
FD260UL-240V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0309 | 9010-0310 |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 19 | 19 |
Recovery time after 30 seconds door open at 150 °C [min] | 5 | 5 |
Temperature fluctuation at 150 °C [± K] | 0.4 | 0.4 |
Temperature range 10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.9 | 1.9 |
Electrical data | ||
Nominal power [kW] | 2.3 | 2.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 240 |
Unit fuse [A] | 12.5 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [mm] | 515 | 515 |
Height [mm] | 780 | 780 |
Width [mm] | 650 | 650 |
Measures | ||
Interior volume [L] | 259 | 259 |
Load per rack [kg] | 40 | 40 |
Net weight of the unit (empty) [kg] | 85 | 85 |
permitted load [kg] | 270 | 270 |
Outer dimensions | ||
Depth net [mm] | 760 | 760 |
Height net [mm] | 965 | 965 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Width net [mm] | 810 | 810 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 410 | 410 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 19 | 19 |
Recovery time after 30 seconds door open at 150 °C [min] | 5 | 5 |
Temperature fluctuation at 150 °C [± K] | 0.4 | 0.4 |
Temperature range 10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.9 | 1.9 |
Electrical data | ||
Nominal power [kW] | 2.3 | 2.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 240 |
Unit fuse [A] | 12.5 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [in] | 20.29 | 20.29 |
Height [in] | 30.73 | 30.73 |
Width [in] | 25.61 | 25.61 |
Measures | ||
Interior volume [cu.ft.] | 9.1 | 9.1 |
Load per rack [lbs] | 88 | 88 |
Net weight of the unit (empty) [lbs] | 187 | 187 |
permitted load [lbs] | 595 | 595 |
Outer dimensions | ||
Depth net [in] | 29.94 | 29.94 |
Height net [in] | 38.02 | 38.02 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Width net [in] | 31.91 | 31.91 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 410 | 410 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
FD 260 |
PDF (109.14 kB) | > |
Operating Manuals |
BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720 |
PDF (10.62 MB) | > |
Operating Manuals |
Quick Start Guide BD | BF | ED | FD | FED series |
PDF (1.53 MB) | > |
Technical Drawings |
Model FD 260 Interior dimensions |
PDF (362.22 kB) | > |
Technical Drawings |
Model FD 260 Access ports |
PDF (101.90 kB) | > |
Technical Drawings |
Model FD 260 Access ports BINDER INDIVIDUAL |
PDF (90.15 kB) | > |
Case Studies |
Drying and heating chambers (Series ED | FD) - Testing the functionality and service life of cables U. I. Lapp GmbH |
PDF (189.08 kB) | > |
Case Studies |
Drying and heating chambers (Series FD) - From toothbrushes to tool handles and seals in vehicles KRAIBURG TPE GmbH & Co. KG |
PDF (701.49 kB) | > |
Case Studies |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
Case Studies |
Drying and heating chambers (Series ED | FD) - Textile research Textilforschungsinstitut Thüringen-Vogtland e.V. |
PDF (833.10 kB) | > |
Case Studies |
Drying and heating chambers (Series FD) - Cocoa beans hitting the spot Seguine Cacao Cocoa & Chocolate Advisors |
PDF (1.17 MB) | > |
Brochures |
Drying and heating chambers E | ED | ED-S | FD | FD-S | FED | FP | M series |
PDF (2.96 MB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |