The BINDER MK series
Environmental simulation chamber for cyclical temperature
The BINDER environmental simulation chamber of the MK series is suitable for heat or cold testing between -40 °C and 180 °C (-40 °F and 356 °F). The APT.line™ preheating chamber technology uniquely simulates a natural environment. For cyclical temperature testing, this environmental simulation chamber is a smart alternative to complex individual solutions.
Advantages:
- State-of-the-art reliability
- User-friendly chamber interior
- Comprehensive standard equipment
Areas of application:
-
Automotive -
Electronics / Semiconductor Industry -
Plastics Industry
| Features | Customer benefits | Characteristics |
|---|---|---|
| APT.line™ climate technology |
|
APT.line™
|
| Standard equipment |
|
Well equipped
|
| Unit design |
|
Good use of space
|
| Production |
|
|
| Accessories and Services |
|
Comprehensive product portfolio
|
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range of -40 °C to 180 °C (-40 °F to 359 °F)
-
MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real-time clock
- Adjustable ramp function via program editor
- 2 access ports Ø 80 mm (3.15 inch), right and left side
- Heated viewing window with LED interior lighting
- Temperature safety device class 2 (DIN 12880), with visual and audible temperature alarm
- Environmentally friendly refrigerant R 404a
- Ethernet interface for communication software APT-COM™ DataControlSystem
- 1 stainless steel rack
- BINDER technical specification conformance certificate
- BINDER Communication software APT-COM™ 3 Basic Edition
| MK 240 (E3.1) | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (incl. 18 mm (0.71 inch) access port with plug) (mm/inch) | 1135 / 44.7 | |
| Height (incl. casters) (mm/inch) | 1715 / 67.5 | |
| Depth (incl. door handle, I-triangle, connection 55 mm (2.17 inch)) (mm/inch) | 1000 / 37.4 | |
| Wall clearance, side (mm/inch) | 300 / 6.3 | |
| Wall clearance, rear (mm/inch) | 200 / 3.9 | |
| Viewing window width (mm/inch) | 508 / 20.0 | |
| Viewing window height (mm/inch) | 300 / 11.8 | |
| Number of doors (ea.) | 1 | |
|
|
Interior dimensions | |
| Width (mm/inch) | 735 / 28.9 | |
| Height (mm/inch) | 700 / 27.6 | |
| Depth (mm/inch) | 443 / 17.4 | |
| Interior volume (l/cu.ft.) | 228 / 8.0 | |
| Racks (number standard/max.) | 1/ 6 | |
| Load per shelf (kg/lbs.) | 30 / 66 | |
| Permitted total load (kg/lbs.) | 70 / 155 | |
| Weight (empty) (kg/lbs.) | 360 / 798 | |
|
|
Temperature data | |
| Temperature range (°C/°F) | -40 - 180 / -40 - 359 | |
| Temperature variation (±K) | 0.1 - 1.2 | |
| Temperature fluctuation (±K) | 0.1 - 0.5 | |
| Mean warm-up rate acc. to IEC 60068-3-5 (°C/min.) | 5 | |
| Mean cooling rate acc. to IEC 60068-3-5 (°C/min.) | 4.5 | |
| Heat compensation, max. (W) | 2000 | |
|
|
Electrical data | |
| IP protection class acc. to EN 50529 | IP 20 | |
| Voltage (± 10 %) 50 Hz (V) | 400, 3 N ~ | |
| Nominal power (kW) | 4.2 | |
| Energy consumption at 20 °C (68 °F) (W) 1) | 1300 | |
| Noise level (approx. dB(A)) | 62 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
BINDER Data Logger Kits
The new BINDER Data Logger Kits – Makes independent recording of temperature data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount
Access port
With silicone plugs for introducing external measuring instruments into the chamber, access ports with 30, 50, 80, 100, 125 mm (1.18, 1.97, 3.15, 3.94, 4.72 inch) diameters
Notch-type access port in door
Provides easy connection of cables to test specimens and facilitates loading and unloading of the chamber. Doors have access ports measuring 100 x 35 mm (3.93 x 1.38 inch), which can be sealed with the included silicone plugs
Reinforced rack
To ensure safe and stable storage of heavy test specimens
APT-COM™ DataControlSystem GLP Edition
Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements
Analog outputs
For temperature or temperature and humidity 4 - 20 mA with 6-pin DIN socket (output cannot be adjusted)
Calibration certificate + validation
BINDER can significantly reduce the workload in qualifying devices. Nobody knows our devices as well and has as much experience in certifications as we do
| MK 240 (E3.1) | |
|---|---|
| Access ports with silicone plug 30, 50, 80, 100, 125 mm (1.18, 1.97, 3.15, 3.94, 4.72 inch) | O |
| Securing elements for additional fastening of racks (1 set of 4 pieces) | O |
| Keyboard lock | O |
| Analog output for temperature 4 - 20 mA with 6-pin DIN socket (output not adjustable) | O |
| Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature | O |
| Extension to factory calibration certificate. Each additional measurement at additional measuring point or testing temperature | O |
| Additional measuring channel for digital display of specimen temperature with flexible PT 100 temperature sensor, measured data recorded via unit interface | O |
| Data Logger Kit T 220: For the continuous temperature recording of -90 °C to 220 °C (-130 °F - 428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit | O |
| Data Logger Software: Configuration and evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) | O |
| Rack, stainless steel | O |
| Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg (154 lbs.) | O |
| Shelf perforated, stainless steel | O |
| Notch-type access port in door, 100 x 35 mm (3.93 x 1.38 inch) | O |
| Temperature safety device for over and under temperature, Class 2 | O |
| Zero-voltage relay outputs accessible via 6-pin DIN socket. Additional module for controlling 3 relay outputs via 3 of the programmable controller's contacts | O |
| RS 422 interface | O |
| Locking door handle with key | O |