The BINDER CO2 incubator - CB series
CO2 incubator with additional process controls
The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.
Advantages:
- Hot air sterilization at 180 °C (356 °F)
- Seamless, deep-drawn inner chamber made of stainless steel
- Unique BINDER technology (patented air jacket system, controlled condensation, etc.)
Areas of application:
-
Bio Tissue Engineering -
In vitro Fertilization (IVF) -
Clinics / University Hospitals
| Features | Customer benefits | Characteristics |
|---|---|---|
| Sterilization |
|
180 °C (356 °F) hot air sterilization
|
| Permadry™ humidity system |
|
Controlled humidification system
|
| APT.line™ heating technology |
|
Preheating chamber with VENTAIR™ air jacket
|
| Gas distribution |
|
Gas mixing head with venturi effect
|
| Inner chamber concept |
|
Seamless, deep-drawn inner chamber
|
| CO2 measurement |
|
Single-beam infrared sensor
|
| Operating costs |
|
|
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth
- Temperature range from 5 °C (9 °F) above ambient temperature to 60 °C (140 °F)
- MCS controller for temperature and CO2 concentration
-
User-friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
- Standard-compliant hot air sterilization at 180 °C (356 °F) (DIN 58947)
- VENTAIR™ Jacket System
- Drift-free infrared CO2 measurement system
- Patented Gas mixing nozzle
- Permadry System - condensation-free double-pan humidification system, maintains dry interior walls
- Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges)
- Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Tightly-fitted inner glass door
- RS 422 interface for communication software APT-COM™ DataControlSystem
- 2 perforated stainless steel shelves for CB 53 with standard equipement and O2 control
- Units are stackable with stacking adapter
- Door lock
- BINDER test confirmation
| CB 53 | ||
|---|---|---|
|
|
Exterior dimensions | |
| Width (mm/inch) | 580 / 22.8 | |
| Height (incl. feet) (mm/inch) | 720 / 28.3 | |
| Depth (plus 55 mm (2.2 inch) for door handle and connection) (mm/inch) | 550 / 21.7 | |
| Wall clearance side (mm/inch) | 50 / 1.97 | |
| Wall clearance rear (mm/inch) | 100 / 3.94 | |
| Number of doors (ea.) | 1 | |
| Inner glass door(s) | 1 | |
|
|
Interior dimensions | |
| Width (mm/inch) | 400 / 15.7 | |
| Height (mm/inch) | 400 / 15.7 | |
| Depth (mm/inch) | 330 / 13.0 | |
| Interior volume (l/cu.ft.) | 53 / 1.9 | |
| Number of shelves (standard/max.) | 2 / 3 | |
| Dimensions shelves width x depth (mm/inch) | 396 x 289 / 15.6 x 11.4 | |
| Load per shelf (kg/lbs.) | 10 / 22.0 | |
| Permitted total load (kg/lbs.) | 30 / 66.1 | |
| Weight (empty) (kg/lbs.) | 60 / 133 | |
|
|
Temperature data | |
| Temperature range from 5 °C (9 °F) above ambient temperature to (°C/°F) | 60 / 140 | |
| Temperature variation at 37 °C (± K) | 0.3 | |
| Temperature fluctuation at 37 °C (± K) | 0.1 | |
| Recovery time after door was opened for 30 sec. at 37 °C (98.6 °F) (min.) 1) | 3 | |
|
|
Humidity data | |
| Humidity (±2% r.h.) | 95 | |
|
|
CO2 data | |
| CO2 range (vol. % CO2) | 0 - 20 | |
| Setting accuracy (Vol.-% CO2) | 0.1 | |
| Recovery time after door was opened for 30 sec. 1) | ||
| at 5.0 vol. % CO2 (min.) | 6 | |
| CO2 measurement | IR | |
| Connection hose nozzle for CO2 for hose with internal diameter (mm/inch) | 6 / 0.24 | |
|
|
O2 data | |
| O2 range (vol. % O2) | 0.2 - 95 | |
| Setting accuracy (Vol.-% O2) | 0.1 | |
| Recovery time after door was opened for 30 sec. 1) | ||
| at 1.0 vol. % O2 (min.) | 25 | |
| at 5.0 vol. % O2 (min.) | 9 | |
| O2 measurement | ZrO2 | |
| Connection hose nozzle for O2 / N2 for hose with internal diameter (mm) | 6 / 0.24 | |
|
|
Electrical data | |
| Voltage (± 10%) 50/60 Hz (V) | 230 | |
| Voltage (± 10%) 60 Hz (V) | 115 | |
| Nominal power (kW) | 1.0 | |
| Energy consumption at 37 °C (98.6 °F) (W) 2) | 70 |
1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
BINDER Gas Supply Service
The external tank changer makes automatic changeover to a second tank possible once the first tank is empty. It has acoustic and visual alarms and is equipped with a zero-voltage alarm output for extreme notification systems. It can be used for maximum two CO2 incubators and is suitable for CO2, O2 and N2 tanks.
Gas-tight, 4-way divided inner glass door
For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and CO2 when loading. Ensures short recovery times.
Control for variable O2 values
For hyper- or hypoxic culture conditions. The O2 or N2 gas supply can be controlled using an additional control loop as needed. A zirconium oxide sensor (ZrO2) is used for the measurement.
Silicone access ports
For introducing external measuring instruments into the chamber. The access ports have a diameter of 30 mm (1.2 inch) and can be sealed on both sides using a silicone plug. They can be positioned on the back, left, and right sides.
Stacking adapter
Used for stacking of two CB incubators which are thermally isolated from each other. The incubators can thus be sterilized with hot air independent of each other. Available as stacking adapters, stacking frames or base frames.
APT-COM™ DataControlSystem GLP Edition
Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements.
Calibration certificate & validation
BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.
| CB 53 | |
|---|---|
| Silicone access port with two silicone plugs, 30 mm (1.2 inch), back | O |
| Lockable controller keyboard | O |
| Gas tank connection set for CO2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose | O |
| Gas tank connection set for O2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose | O |
| Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m (16.4 ft.) hose | O |
| BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either CO2 or N2, with audible and visual alarms, as well as potential-free alarm output | O |
| Unit conversion from RS 422 to Ethernet interface | O |
| 4 - 20 mA analog outputs for temperature and CO2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable) | O |
| Switched LEMO inner chamber socket (coverable) and LEMO connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) | O |
| Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the CO2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door | O |
| Calibration certificate for temperature and CO2 (temperature measurement in center / CO2 measurement performed using analyzed test gas at 37 °C (98.6 °F) and 5% CO2 | O |
| Calibration certificate for optional O2 control, O2 measurement with analyzed test gas 1% O2 | O |
| Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C (98.6 °F) or at specified temperature with measuring protocol and certificate | O |
| Manual for Primary Human Cell Culture, in English | O |
| Perforated shelf, stainless steel | O |
| Shelf, stainless steel for devided gas-tight inner glass door | O |
| Base on casters | O |
| Stacking adapter for direct thermal decoupled stacking of two C 53 CO2 incubators | O |