Size ranges of KBF LQC series

Constant climate chamber with additional photometry

The special advantage of the BINDER KBF LQC series: the patented photometry for photostability testing. Two spherical 3D ball-type sensors capture visible light intensity and UV light intensity – if the desired light dosage is achieved, the KBF LQC constant climate chamber switches off automatically.


Advantages:

  • Long-term stable test conditions
  • Independent of the water supply
  • one-stop solution: Temperature/humidity/light simulation in one chamber
Areas of application:
Pharmaceuticals Industry
Pharmaceuticals Industry
Features Customer benefits Characteristics
APT.line™ climate technology
  • Same test conditions throughout the chamber interior
  • Independent of specimen size and quantity

APT.line™

  • Constant and gentle circulation of air through large-surface side walls even under a full load
  • Homogeneous climate conditions throughout test specimens
Photostability tests
  • Light uniformity for all specimens on the entire shelf
  • Flexible use for Q1A and/or Q1B
  • Automatic photostability tests under consistent conditions

Realistic light photometry in 3D

  • ICH-compliant illumination with BINDER Q1B Synergy Light™
  • Removable illumination cassettes
  • Spherical 3D ball-type sensors
Water supply
  • Flexible solution independent of water supply and installation site
  • Easy plug-and-play handling
  • Direct connection to the domestic water system
  • Convenient water treatment with BINDER PURE AQUA SERVICE
  • Sewage pump for discharges up to 1 m in height
Humidification system
  • Very accurately measured values
  • Minimal maintenance requirements
  • FDA-compliant test results
  • Vapor pressure humidification for fast response times
  • Drift-free, capacitive humidity sensor
  • Short recovery time after door opening
Cooling system
  • Reliable test results even under extreme climate and site conditions
  • Stable, long-term tests according to GLP/GMP
  • Large power reserves, e.g. for lighting applications
  • Powerful compressor cooling system for ambient temperatures up to 32 °C (89.6 °F)
  • No freezing thanks to double evaporator plate
Standard equipment
  • No extra costs
  • Chamber is easily moved on casters
  • Condensation-free glass door for clear viewing and constant climate

Comprehensive standards

  • Ethernet interface
  • Access port diameter 30 mm (1.2 inch)
  • Casters from 240 l (8.6 cu.ft.) volume
  • Inner glass door with seal and double outer door seal
  • Door heated against condensation
Controller
  • All measured values read at a glance
  • Convenient documentation
  • Easy operation
  • Convenient HMI (Human Machine Interface)

MCS screen controller

  • 25 program memory
  • Digital continuous-line recorder for monitoring limits
  • Alarm function
Qualification
  • FDA- and GLP/GMP-compliant documentation
  • Maximum process stability
  • FDA approved for several years

More than 10 years of experience with:

  • GLP/GMP, IQ, OQ, PQ, DQ
  • FDA-compliant software APT-COM™
  • Years of proven and recognized validation and documentation materials
Accessories and Services
  • Complete solution
  • Everything from one source
  • BINDER Service is always nearby
  • Various options: BINDER Data Logger Kits, GLP compliance, access ports in various sizes and positions, object temperature measurement
  • Worldwide service network
  • Electronically controlled APT.line™ preheating chamber and refrigerating system assuring temperature accuracy and reproducible results
  • 3 variable positioned illumination cassettes with BINDER Q1B Synergy Light™ for unique homogenous light distribution
  • Illumination is specified for stability in accordance with ICH guideline Q1B, option 2
  • Light Quantum Control LQC, precise measurement and integration of light intensity and ultraviolet light intensity directly at the sample location, automatic deactivation after reaching the wanted light dosage
  • Temperature range 0 °C to 70 °C (32 °F to 158 °F) (without illumination and humidity)
  • Temperature range 20 °C to 60 °C (68 °F to 140 °F) (with illumination and humidity)
  • Humidity range 10 % to 80 % RH (without illumination)
  • Humidity range 10 % to 75 % RH (with illumination)
  • MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
    • User friendly LCD screen
    • Easy-to-read menu guide
    • Integrated electronic chart recorder
    • Variety of options for the graphic display of process parameters
    • Real time clock
  • Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A (R2)
  • Inner glass door with sealing
  • Independent adjustable temperature safety device class 3.1 (DIN 12880), with visual and audible temperature alarm
  • Access port with silicone plug Ø 30 mm (1.18 inch), left side
  • Safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.)
  • Ethernet interface for APT-COM™ DataControlSystem software
  • 3 stainless steel racks
  • BINDER technical specification conformance certificate
KBF LQC 720 (E5.2)
Exterior dimensions
Width (mm/inch) 1255 / 49.4
Height (incl. casters) (mm/inch) 1925 / 75.8
Depth (incl. door handle, I-panel, connection 80 mm/ 3.15 inch) (mm/inch) 970 / 38.2
Wall clearance, rear (mm/inch) 100 / 3.9
Wall clearance, side (mm/inch) 200 / 7.9
Steam space volume (l/cu.ft.) 918 / 32.4
Number of doors (ea.) 2
Inner glass door (ea.) 2
     
Interior dimensions
Width (mm/inch) 973 / 38.3
Height (mm/inch) 1250 / 49.2
Depth (mm/inch) 576 / 22.7
Interior volume (l/cu.ft.) 700 / 24.7
Racks (number standard/max.) 3 / 12
Load per rack (kg/lbs.) 45 / 99
Permitted total load (kg/lbs.) 150 / 331
Weight (empty) (kg/lbs.) 374 / 826
     
Temperature data (without humidity)
without illumination cassettes (°C/°F) 1) 0 - 70 / 32 - 158
with illumination cassettes, with illumination (°C/°F) 1) 10 - 60 / 50-140
Max. heat compensation up to 40 °C (104 °F) with illumination (W) 1000
     
Climate data (with humidity)
Temperature range without illumination cassettes (°C) 1) 0 - 70 / 32 - 158
Temperature range with illumination cassettes with illumination (°C) 1) 20 - 60 / 68 -140
Temperature variation with illumination
at 25 °C (77 °F) and 60 % RH (± K) 1.2
at 40 °C (140 °F) and 75 % RH (± K) 1.2
Temperature fluctuation with illumination
at 25 °C (77 °F) and 60 % RH (± K) 0.2
at 40 °C (140 °F) and 75 % RH (± K) 0.2
Humidity range without illumination cassettes (% RH) 10 - 80
Humidity range with illumination cassettes, with illumination 1) (% RH) 10 - 75
Humidity fluctuation with illumination
at 25 °C (77 °F) and 60 % RH (± % RH) 2
at 40 °C (140 °F) and 75 % RH (± % RH) 2
Recovery time after doors were open for 30 sec.
at 25 °C (77 °F) and 60 % RH with illumination (min.) 1
at 40 °C (104 °F) and 75 % RH with illumination (min.) 5
Illumination data per light cassette
ICH-compliant illumination device for photostability testing (Lux) / (UVA W/m²) 9.000 / 1,5
     
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10 %) 50/60 Hz (V), 1~ 200-240
Voltage (± 10 %) 50 Hz (V), 1~ 200-230
Nominal power at 240 V (kW) 3.5
Energy consumption at 40 °C (104 °F) / 75% RH 1) (W) 2350
Noise level approx. (dB (A)) 53

BINDER Light Quantum Control (LQC)

2 spherical sensors for non-directional measurement, directly at the sample location

Temperature-humidity chart without illumination

A: Guaranteed condensation free range / B: Temporary usable operation (up to 24 h)

Temperature-humidity chart with illumination

A: Guaranteed condensation free range / C: Deviation of technical data may be possible

Heat compensation without illumination

Heat compensation with illumination

Light spectrum

1) These values can be used for dimensioning air condition systems.

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

BINDER PURE AQUA SERVICE

BINDER PURE AQUA SERVICE

BINDER PURE AQUA SERVICE is used to treat or fully desalinate tap water if the water quality is insufficient. The ion ex-change system consists of a housing, an integrated filter cartridge and a filter head. The digital quality-monitoring system is integrated in the filter head of the BINDER PURE AQUA SERVICE and uses 10 LEDs to display the current operating condi-tion of the filter medium.

BINDER Data Logger Kits

BINDER Data Logger Kits

The new BINDER Data Logger Kits – Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount

External water supply set

External water supply set

External water supply set from fresh and waste water container, wiring and pump

Access port

Access port

With silicone plugs for introducing external measuring instruments into the chamber, access ports with 30, 50 or 100 mm (1.18, 1.97, 3.94 inch) diameters

APT-COM™ DataControlSystem GLP Edition

APT-COM™ DataControlSystem GLP Edition

Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements

Calibration certificate & validation

Calibration certificate & validation

BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do

Temperature measurement of the specimen

Temperature measurement of the specimen

Additional PT 100 temperature sensor for accurate temperature measurement of the specimen and digital display of measured values. Recording of measured data via Ethernet or RS 422 interface optional

KBF LQC 720 (E5.2)
Access ports with silicone plug 30, 50, 100 mm (1.18, 1.97, 3,94 inch) O
Securing elements for additional fastening of racks (1 set of 4 pieces) O
Keyboard lock O
RS 422 interface for communication software APTCOM™ DataControlSystem O
Additional PT 100 temperature sensor, flexibly installed, with external connection, including DIN connector (6-pin) O
Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 °C (77 °F) / 60 % RH or at specified values O
Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values O
Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at (25 °C /77 °F) / 60% RH or at specified values O
External fresh water supply set consits of fresh and waste water tank with 20 l (0.7 cu.ft.) each, cabling and pump O
BINDER PURE AQUA SERVICE O
Disposable cartridge for BINDER PURE AQUA SERVICE O
External chart recorder for temperature and humidity O
Data Logger Kit TH 70: For the continuous temperature and humidity recording of -40 °C (-40 °F) to 70 °C (158 °F) / 0% to 100 % RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit O
Data Logger Kit TH 70/70: With two attachable combined sensors. One for the continuous temperature and humidity recording of -40 °C (-40 °F) to 70 °C (158 °F) / 0% to 100 % RH. Second one at the data logger for recording the environmental conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors with 2 m extension cable and 1 fixture for the connection at the BINDER unit O
Data Logger Kit T 220: For the continuous temperature recording of -90 °C (-130 °F) to 220 °C (428 °F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit O
Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) O
Rack, stainless steel O
Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg (154 lbs.) O
Shelf, perforated, stainless steel O
Temperature safety device, class 3.3 (DIN 12880) with visual alarm O
4-20 mA analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6-pin DIN socket. Outputs are adjusted automatically as the controller is adjusted O
Zero-voltage relay alarm outputs for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket, with audible signal that can be switched off (maximum power rating 24 V AC/DC, 2.5 A) O
Locking door handle with key O
Replacement set illumination tubes for one illumination cassette, including 3 cool white fluorescent tubes and 2 BINDER Q1B Synergy Light™ fluorescent tubes O


Contact

Are you interested in further information on products and services?

Contact us
Technical support

Do you have a technical problem and need assistance in trouble-shooting?

Use our service form.

Request technical service
Newsletter subscription
Product inquiry KBF LQC 720 (E5.2)

Interested in


Your details


Data storage and data sharing


Please fill in all required fields

(*) Required fields