Precision combined with maximum dynamics. KBW exceeds any requirements with respect to optimal lighting and temperature conditions for exactly defined culture processes. Extremely short reaction times keep all growth parameters in equilibrium -- natural simulation as never before. Handling is truly enhanced by the integrated real-time clock function in the controller.
- Electronically controlled APT.line™ preheating chamber technology
- Temperature range: -10 °C to 60 °C (14 °F to 140 °F) without illumination
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections for programming day/night cycles
- The time interval of single program sections can be adjusted up to a maximum of either 99:59 hours or 999:59 hours. This adjustment applies to all program sections.
- Integrated week program timer with real time function
- Time functions: delayed ON, delayed OFF, and temperature-dependent delayed OFF
- Adjustable ramp functions via program editor
- Adjustable fan speed (0 to 100 %)
- Elapsed time indicator
- Illumination: flexible illumination cassettes with 4 daylight fluorescent tubes each (KBW 720 with 8 tubes), switchable (OFF – 50 % – 100 %)
- Access port, Ø 30 mm (1.2 inch) , right side, top and bottom
- Inner glass door
- Independent adjustable temperature safety device, Class 3.1 (DIN 12880) with visual and acoustic alarm
- Environmentally friendly refrigerant R 134a
- RS 422 interface for communication software APT-COM™ DataControlSystem, or switch over to printer output with RS 232 / RS 422 interface converter
- Adjustable intervals for printer
- Flexible illumination cassettes with daylight fluorescent tubes
- Stainless steel shelves
- BINDER test certificate
| KBW 240 | KBW 400 | KBW 720 | |
| Exterior dimensions | |||
| Width (mm/inch) | 1034 / 40.7 | 884 / 34.8 | 1234 / 48.6 |
| Height (inclusive feet/castors) (mm/inch) | 1142 / 45.0 | 1850 / 72.8 | 1816 / 71.5 |
| Depth (mm/inch) | 746 / 29.4 | 716 / 28.2 | 867 / 34.1 |
| Plus door handle, I-panel, connection (mm/inch) | 100 / 3.9 | 100 / 3.9 | 100 / 3.9 |
| Wall clearance (mm/inch) | 100 / 3.9 | 100 / 3.9 | 100 / 3.9 |
| Wall clearance with open door(s) (mm/inch) | 160 / 6.3 | 160 / 6.3 | 160 / 6.3 |
| Steam space volume (l/cu.ft.) | 308 / 10.9 | 515 / 18.2 | 855 / 30.2 |
| Number of door(s) / inner glass door(s) | 2 | 1 | 2 |
| Interior dimensions | |||
| Width (mm/inch) | 800 / 31.5 | 650 / 25.6 | 1000 / 39.4 |
| Height (mm/inch) | 600 / 23.6 | 1308 / 51.5 | 1168 / 46.0 |
| Depth (mm/inch) | 500 / 19.7 | 470 / 18.5 | 600 / 23.6 |
| Interior volume (l/cu.ft.) | 240 / 8.5 | 400 / 14.1 | 700 / 24.7 |
| Load per shelf (kg/lbs.) | 30 / 66 | 20 / 44 | 45 / 99 |
| Permitted total load (kg/lbs.) | 70 / 155 | 100 / 221 | 100 / 221 |
| Weight of the unit (empty) (kg/lbs.) | 160 / 353 | 236 / 521 | 262 / 578 |
| Shelves (number standard/max.) | 2/7 | 3/15 | 3/14 |
| Flexible adjustable illumination cassetts | 2 | 3 | 3** |
| Temperature data | |||
| Temperature range | |||
| at 0 % illumination (°C/°F) | -10–60 /14–140 | -10–60 /14–140 | -10–60 /14–140 |
| at 100 % illumination (°C/°F) | 14-60 / 57–140 | 14-60 / 57–140 | 30-60 / 57–140 |
| at 0 % illumination with option reinforced refrigeration (°C/°F) | -10,0-60,0/ 14–140 | -10,0-60,0/ 14–140 | -10,0-60,0/ 14–140 |
| at 100 % illumination with option reinforced refrig. (°C/°F) | 0-60 / 32–140 | 0-60 / 32–140 | 9-60 / 48–140 |
| Temp. range 100 % high intensity illumination and reinforced refrigeration | |||
| 1 shelf (°C/°F) | 0–60 / 32–140 | -3–60 / 27–140 | 12–60 / 54–140 |
| 2 shelves (°C/°F) | 22–60 / 72–140 | 12–60 / 54–140 | - |
| 3 shelves (°C/°F) | - | 33–60 / 91–140 | - |
| Temperature variation | |||
| at 0 °C (32 °F), 0 % / 100 % illumination / reinforced refrigeration (± °C) | 0,7/2,5 | 0,7/2,9 | 0,7/- |
| at 25 °C (77 °F), 0 % / 100 % illumination (± °C) | 0,4/3,6 | 0,5/4 | 0,5/- |
| at 25 °C (77 °F), 100 % illumination / reinforced refrigeration (± °C) | 3,4 | 2,8 | 3,5 |
| Temperature fluctuation | |||
| during heating operation (± °C) | 0,1 | 0,1 | 0,1 |
| during cooling operation (± °C) | 0,3 | 0,3 | 0,3 |
| Heating up time at 37 °C (98.6 °F), 0 % / 100 % illumination 1) (Min.) | 22/15 | 26/22 | 22/28 |
| Cooling down time room temperature | |||
| at 4 °C (39.2 °F), 0 % illumination 1), 2) (Min.) | 77 | 120 | 125 |
| at 4 °C (39.2 °F), 0 % / 100 % illumination / reinforced refrigeration 1) (Min.) | 30/47 | 39/84 | 62/- |
| Recovery time after door was opened for 30 sec. | |||
| at 4 °C (39.2 °F), 0 % illumination 1)(Min.) | 5 | 8 | 10 |
| at 4 °C (39.2 °F), 0 % / 100 % illumination / reinforced refrigeration (Min.) | 3/5 | 3/5 | 5/- |
| at 37 °C (98.6 °F), 0 % / 100 % illumination (Min.) | 3/2 | 2/3 | 2/4 |
| Max. illumination intensity / daylight illumination tubes 3) | |||
| (Lux) / μE/(s x m2)* / ( W/m2) UVA | 9000 / 95 / 0.7 | 12000 / 125 / 0.65 | 13000 / 225/ 1.17 |
| Max. illumination intensity / high-intensity illumination 3) | |||
| (Lux) / μE/(s x m2)* / ( W/m2) UVA | 25000 / 370 / 2.2 | 28600 / 430 / 2.3 | 30000 / 774 / 4.1 |
| Max. illumination intensity / growth lamps 3) (Lux) / μE/(s x m2)* | 4000 / 75 | 6300 / 77 | 7200 / 138 |
| Electrical data | |||
| Housing protection acc. to EN 60529 | IP 20 | IP 20 | IP 20 |
| Nominal voltage (±10 %) 50/60 Hz (V) | 230 / 115 | 230 / 115 | 230 / 115 |
| Nominal power (W) | 1100 | 1350 | 2000 |
| Energy consumption 2) at 37 °C (W) | 100 | 90 | 160 |
1) up to 98 % of the set value
2) these energy consumption values can be used upon calculation of air conditioning systems
3) Mean values based on 9 measuring points. The distance between the measuring plain and each illuminated shelf is 12 cm (4.7 inch).
* Light measurement using Quantum sensors with cosinus correction positioned vertically upside.
** KBW 720 / 115 V: Standard equipped with 2 illumination cassettes and 2 shelves stainless steel.
All specified technical data apply for standard equipment operating at an ambient temperature of + 20 °C (68 °F), with line voltage fluctuations of ± 10%. These typical average values for series equipment were determined in accordance with the BINDER factory standard. They are based upon the recommended distances from the inner chamber walls, namely 10% of height, width and depth. Differing ambient temperatures or variances in the design of individual equipment may produce different performance data.
We therefore recommend that equipment be calibrated and/or validated on a case-by-case basis when working at the extremes of the permissible ambient temperature range.