Heating chambers from the APT.line™
FED 53
Heating chamber with forced convection
The FED series is a true all-rounder. It has a virtually unlimited capacity and is at the same time particularly adaptable to the specific requirements of a large variety of testing applications. The enhanced time functions and the digitally controlled air turbine can be used to adjust ideal temperature parameters and recirculation air conditions.
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- Temperature range 5 °C (32 ºF) above ambient temperature up to 300 °C (572 °F)
- MS controller with serveral timer functions
- Controller timer functions: delayed ON, delayed OFF, temperature dependent delayed OFF
- Digital temperature setting with an accuracy of one degree
- Adjustable fan speed
- Front ventilation flap slide and rear exhaust duct Ø 50 mm (1.97 inch)
- Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
- RS 422 interface for communication software APT-COM™ DataControlSystem, or switch over to printer output with RS 232 / RS 422 interface converter
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test certificate
|
1) value without window
2) up to 98 % of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.
-
Access ports
With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50 and 100 mm (0.4, 1.2, 2, 3.9 inch) diameter.
-
Door with window and interior lighting
For optimum process control in the interior, available for all equipment sizes.
-
Lockable door
Prevents unauthorized access and interference with processes in the chamber.
-
Calibration certificates
Measurement in the center at specified values. Additional measuring points or test values according to your specification.
|
||
| FED 53 | ||
| Access port with silicone plugs, 10 mm (0.39 inch), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) | O | |
| HEPA fresh - air filter, Class EU14 (according to EN 1822; min. 99.999% for 0.3 µm particles) | O | |
| Independent adjustable temperature safety device, Class 3.1 (DIN 12880) | O | |
| Analog temperature output, 4 - 20 mA, with 6 - pin DIN socket (output not adjustable) | O | |
| Anti - slip rubber pads for safe stacking (4 pieces) | O | |
| Temperature measurement acc. to DIN 12880 (27 measuring points) at 150 °C (302 °F) or at specified temperature with measuring protocol and certificate | O | |
| Factory calibration certificate. Measurement in center of chamber at 150 °C (302 °F) or at specified testing temperature | O | |
| Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature | O | |
| Over temperature alarm, acoustic, can be switched off. Temperature limit can be set at the independent, adjustable temperature safety device class 2 | O | |
| Measurement of air change rate according to ASTM D5374, with definition and protocol | O | |
| Rack, chrome - plated or stainless steel | O | |
| Shelf, perforated, stainless steel | O | |
| Lockable door | O | |
| FKM door gasket | O | |
| Inert gas connection (gas inlet and outlet) | O | |
| Mostly gas - tight version | O | |
| Door with window and interior lighting, 15 W (230 x 230 mm / 9.06 x 9.06 inch) | O |