CO2 incubators from the APT.line™
C 150
The new STANDARD in CO2 incubators
The C 150 sets new standards for cell cultivation: contamination-free as a result of hot air sterilization at 180 °C, stable pH thanks to a drift-free FPI infrared measurement system, superior temperature precision with excellent dynamics, and an interior that is condensation-free even at high humidity levels to ensure best growth results. Used stand alone or as a stack the C 150 is easily accessible.
- Air jacket system assuring temperature accuracy and reproducible results
- Temperature range 7 °C (13 °F) above ambient up to 50 °C (122 °F)
- Water pan with built-in condensation control maintains dry interior walls
- Standard compliant 180 °C (356 °F) hot air sterilization using an overnight cycletime (acc to. DIN 58947, Pharmacopoeias, ANSI)
- Weldless deep-drawn inner chamber made of stainless steel with integrated shelf support system
- Drift free infrared CO2 measurement system
- Microprocessor with LED display for temperature and CO2-concentration
- Various alarm and status displays
- Automatic diagnostic system with optical and audible alarm, as well as zero-voltage relay contact for central monitoring
- Lockable controller keyboard via 3 digit password
- Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
- Gas mixing head
- Tightly-fitting inner glass door
- Door Lock
- Door hinged left or right, factory fitted
- Units are stackable with stacking adapter
- 3 perforated shelves made of stainless steel
- BINDER test certificate
- Two BINDER CO2-incubators, stacked:
- Two incubators C 150 series, incl. stacking adapter, ensuring direct thermal decoupled stacking
|
1) up to 98 % of the set value
2) The recovery times of the gas concentration inside the chamber following a door opening refer to an inlet pressure of 2.0 bars (psi).
All technical data is specified for units with standard equipment at an ambient temperature of 25 °C (77 °F) and a mains voltage fluctuation of +5%/-10%. The temperature data is determined in accordance to factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.
-
Cleaning kit
Halogenfree detergents for gentle cleaning of interior chamber without causing corrosion:
- Mild cleaner for stainless steel to provide long -therm-protection
- Clinically approved disinfectant
- Cleaning cloth -
Calibration certificate for temperature and CO2
Factory calibration certificate for temperature and CO2. Temperature measurement in center / CO2 measurement performed using analyzed test gas at 37 °C (98.6 °F) and 5 % CO2.
|
||
| C 150 | ||
| Silicone access port on both sides closable with two silicone lids 30 mm (1.18 inch), left side | O | |
| Silicone access port on both sides closable with two silicone lids 30 mm (1.18 inch), right side | O | |
| Shelf, perforated, stainless steel | O | |
| Base on castors | O | |
| Stacking adapter C 150 / CB 150 for direct thermal decoupled stacking of a CB 150 / C 150 combination | O | |
| Stacking adapter for direct thermal decoupled stacking of two C 150 CO2 incubators | O | |
| Factory calibration certificate for temperature and CO2. Temperature measurement in center / CO2 measurement performed using analyzed test gas at 37 °C (98.6 °F) and 5 % CO2 | O | |
| Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 °C (98.6 °F) or at specified temperature with measuring protocol and certificate | O | |
| BINDER Gas Supply Service: External gastank changer for connection of 2 gastanks, either CO2 or N2, with audible and visual alarm and zero-voltage alarm output | O | |
| Gastank connection kit for CO2, consisting of a gastank pressure regulator, max. pressure 10 bar, with connection parts, and a (5 m / 16.4 ft.) hose | O | |
| 4-20 mA analog output for temperature and CO2 measurements (e.g. chart recorder connection), with 6-pin DIN socket (output not adjustable) | O | |
| Cleaning kit for equipment maintenance and disinfection, consisting of pH - neutral detergent (1000 g / 2.21 lbs., concentrate), spray disinfectant (500 ml / 0.13 gal. ready - for - use solution) and lint - free cleansing tissues | O | |
| Manual for Primary Human Cell Culture | O |