Size ranges of UF V series

ULTRA.GUARD™ ultra low temperature freezer

The new BINDER ULTRA.GUARD™ ultra low temperature freezer ensures safe long-term storage of samples at -86 °C. This ultra low temperature freezer is based on a multi-stage security concept, which offers everything that laboratory staff want from reliable operation to ease of use and system integration to the emergency exchange service!


Advantages:
  • GUARD.CONTROL™ opens the freezer by pressing a button
  • GUARD.CONTROL™ RFID technology personalizes access and records user traffic
  • DATA.SECURE™ Data logger with USB connection
  • SERVICE.PRO™
     - provides 24/7/365 exchange service
     - and an extended 4 year guarantee
Areas of application:
  • Biotechnology
    Biotechnology
  • Clinics / University Hospitals
    Clinics / University Hospitals
  • Pharmaceuticals Industry
    Pharmaceuticals Industry
BINDER UF V series
Features Customer benefits Characteristics
GUARD.CONTROL™
  • Freezer can be opened and closed effortlessly
  • Automatic door system permits comfortable and safe operation
  • Rapid access
  • Secure sample storage
  • Defined user group
  • Access records
  • Extended data storage

“Push-button“ operation

  • Automatic electronically controlled door mechanism

Unique: advanced RFID Technology

  • RFID key card controlled access and availability of a large protocol database
VIP.COMPLETE™
  • Superior energy efficiency
  • Low energy and operating costs

Insulation design: Internal vacuum insulation panels (VIP)

  • Large surface insulation around all 5 sides
  • Optimized utilization of internal space due to the narrow VIP design (can accommodate up to 52.800 samples)
DATA.SECURE™
  • Easy data transmission with PC requires no extra software (PDF Reader)
  • Supports FDA guideline 21 CFR Part 11
  • Different network versions adaptable to customer specific requirements

Easy Data Monitoring

  • Recording of temperature using a USB data logger
  • Integrated PT 100 provides independent data recording
  • Communication interfaces as part of standard equipment
Noise level
  • Quiet operating environment
  •  49 dB(A)
Operation
  • Easy operation
  • Prevents manipulation
  • Simple relocation
  • Leveling and positioning at point of application
  • Password protection
  • Solid, large casters for in-situ positioning with adjustable feet
  • Easy air filter access, no tools needed
Deicing kit
  • Comfortable and easy deicing routine requires no personnel
  • Deicing tray for convenient discharge of water from deicing
SERVICE.PRO™
  • Increased safety features
  • In the long term high quality guarantees
  • 6-years SERVICE.PRO™
Options and accessories
  • A single-source solution
  • Maximum process safety
  • Extensive accessories
  • Validation and documentation records
  • FDA-compliant APT-COM™ documentation software
  • Temperature range: -86 °C to -40 °C
  • GUARD.CONTROL automatic door mechanism for easy door opening and closing
  • Personalized access control with RFID technology
  • Vacuum Incuslation Panels (VIP) on 5 sides
  • Two-stage cascade refrigeration system with hermetically-sealed compressors
  • Non-flammable refrigerant, CFC-free, proven industrial standard
  • User-friendly microprocessor controller with LED display
    • Easy to read digital display
    • Alarm test system
  • Built-in visual and audible alarm system for power failure, impermissible temperature deviation or battery failure
  • Battery-operated back-up system
    • provides full functionality of alarm functions in case of power failure for 72 hours
    • Improved battery life due to controlled charging
  • Heated duplex door gasket reduces icing
  • Multiple standard communication interfaces:
    • RS 422 interface
    • Potential-free contact
    • Analog output 4-20 mA
  • Inner chamber made of high-quality stainless steel
  • Robust, adjustable and lockable casters
  • Easy air filter replacement without tools
  • SERVICE.PRO 2-year warranty
  • BINDER test confirmation
UF V 500
Exterior dimensions
Width including hinges, housing of door lock and controller (mm) 900
Height including vertically adjustable castors (mm) 1970
Depth (mm) 890
Depth including power connection, housing of door lock and controller (mm) 935
Wall clearance rear (mm) 100
Wall clearance side (side without hinges) (mm) 100
Wall clearance side (side with hinges) (mm) 245
     
Interior dimensions
Number of compartments 4
Number of shelves 3
Width of interior (mm) 619
Width of shelf (mm) 588
Height of interior (mm) 1300
Depth of interior / Depth of shelf (mm) 600
Interior volume, total (l) 483
Permitted load of individual compartment (kg) 50
Permitted total load (kg) 200
Weight of the unit (empty) (kg) 320
     
Temperature data
Control range (°C) -86 to -40
Setting range (°C) -90 to -40
Average temperature variation (±K) 3) 2,5
Cooling down time from +25 °C to -80 °C (h) 1) 5
Heating up time in case of power failure from -80 °C to -60 °C (h) 3
     
Electrical data
IP protection class according to EN 60529 20
Nominal voltage (±10 %) 50 Hz (V) 230
Energy consumption at -80 °C and Tu = 25 °C (KWh/day) 12,8
Average heat dissipation at set value -80 °C and Tu = 25 °C (W) 2) 535
Noise level (dB(A)) 49

Pull-down-time

Pull-down-time with no load at 25 °C ambient temperature

Pull-up-time

Pull-up-time at power faillure with no load at 25 °C ambient temperature

1) to 98% of the set value with empty freezer
2) These values can be used for evaluation of air-conditioning systems.
3) at -80 °C

All technical data are specified for unloaded units with standard equipment at an ambient temperature of +25 °C and a voltage fluctuation of ±10%. The temperature data are determinated in accordance to BINDER factory standard following DIN 12880 respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

PDF Data logger

PDF Data logger

All in one Data logger with USB port. Independent temperature data recording compliant with FDA guideline 21 CFR Part 11. Plug-and-play data transfer requires no software (PDF reader).

Freezer racks and boxes

Freezer racks and boxes

  • Side Access Racks made of stainless steel or aluminum for 50 mm boxes, for 5x4 or 6x4 boxes, empty or filled with standard boxes
  • Sliding Drawer Racks  made of stainless steel, for 50 mm boxes, for 5x4 or 6x4 boxes, empty or filled with standard boxes
  • Standard boxes 50 mm, with dividers (9x9 grid) for 81 samples made of water-repellent cardboard, white
Defrosting kit

Defrosting kit

The de-icing kit consists of a scraper, a wiper and a deicing tray that is easy to install and that guarantees controlled water runoff – ideal for clean and easy de-icing.

Freezer gloves

Freezer gloves

For easy and safe handling of Freezer racks, medium size.

UF V 500
Access port 30 mm, rear panel O
Sealing kit for access port 10 mm, rear panel O
Door hinge right or left O
36 boxes with dividers O
Side Access Rack UF V 5x4, for 50 mm boxes O
Side Access Rack UF V 5x4, filled with 50 mm boxes O
Side Access Rack UF V 6x4, for 50 mm boxes O
Side Access Rack UF V 6x4, filled with 50 mm boxes O
Aluminium Side Access Rack UF V 5x4, for 50 mm boxes O
Aluminium Side Access Rack UF V 5x4, filled with 50 mm boxes O
Aluminium Side Access Rack UF V 6x4, for 50 mm boxes O
Aluminium Side Access Rack UF V 6x4, filled with 50 mm boxes O
Sliding Drawer Rack UF V 5x4, for 50 mm boxes O
Sliding Drawer Rack UF V 5x4 mm, filled with 50 mm boxes O
Sliding Drawer Rack UF V 6x4, for 50 mm boxes O
Sliding Drawer Rack UF V 6x4, filled with 50 mm boxes O
Deep temperature gloves, medium size O
Magnetic bag, DIN A4 O
CO2 back up system O
Ethernet interface O
Additional PT 100 sensor with lemo socket O
Remote alarm box GSM O
Advanced voltage booster O
Read-out box RFID system O
PDF Data logger with USP port O
Chart recorder O
Defrosting kit including de-icing tray, wiper and scratch O
Water cooling O